User’s Manual
34
Method two: Click
Setting
of the day you want to set. Select the check box in
front of the time period to enable it. Enter start time and end time of that time
period.
Select
All
or the check box of any other day, and the set time period will apply to
the selected days.
You can set 6 time periods per day.
Click
Save
.
2)
Configure other parameters as needed. For details, see Table 4-4. For alarm rules of
Step 7
different regions, see Table 4-5.
Table 4-4
Region management parameter descriptions
Name
Description
Effective Object
Select monitoring target to be monitored from
Human
and
Vehicle
.
Direction
Set the alarm direction for tripwire. A->B, B->A, and A<->B are available.
Alarm Type
Set alarm type for intrusion. Alarm, pre-warning, and shield are available.
Priority: Shield > Alarm > Pre-warning. See "Table 4-5 Region alarm rule
descriptions" for details.
Speed Filtering
Objects whose speeds are not within the specified target speed range will not
trigger alarms.
For 50 m and 120 m radars, the speed range must be within 1 to 40 km/h; for 240
m radar, the range must be within 1 to 72 km/h; for 300 m and 450 m radars, the
range must be within 1 to 80 km/h.
Record
By selecting
Record
, the system will record automatically when the alarm is
triggered.
Before enabling this function, you need to configure record period in
Setting >
Storage > Schedule > Record
. For details, see "4.4.1.1 Record
Schedule." In
Setting > Storage > Record Control
, select
Auto
for the
Record Mode
.
When the alarm track is enabled, the radar will control the camera to
record, and the record rules of the camera are invalid. When the alarm
track is disabled, the radar will not control the camera, and the camera
will record under its own recording rules.
Record Delay
The alarm record keeps running for the defined time (from 10 s to 300 s) after
the alarm is ended.
Relay-out
By selecting
Relay-out
, the corresponding alarm output device will be linked
through alarm output port when the alarm is triggered.
Five alarm output ports. Only 50 m/120 m radar supports high power device
control. No.5 is connected to the high power device.