- 71 -
12. MAINTENANCE AND TROUBLESHOOTING (continued)
No. Trouble
Cause
Solution
8
When pressing
the torch
switch, high
frequency is
generated but
no arc is output.
When electrode
touches on the
base metal, arc
is output.
Electrode gets white.
Polish electrode.
Electrode is too thick. Current
setting is too low.
Set to the proper
electrode and
current.
When
measuring
output voltage
in STICK mode,
no –load
voltage is
generated.
Trouble with the main circuit of
inverter.
After turning off the
power switch, contact
your dealer.
No-load voltage
is generated.
Trouble with the control circuit.
Check for PCB
P10346P and
P10535U.
9
WCR keeps working.
Trouble with the hole current
detector CT2
Inspect the hole
current detector CT2.
Trouble with the WCR circuit
After inspecting PCB
P10346P, replace it if
necessary.