- 53 -
10. OPERATION (continued)
CAUTION
٨
The welding conditions (electronic data) stored by this function are susceptible to
occurrence of static electricity, impact, repair, etc., and there is a possibility that the
storage contents may be changed or lost. BE SURE TO MAKE A COPY FOR
IMPORTANT DATA.
٨
Please note that we shall not assume any responsibility for any change or loss of
electronic data resulting from repair.
While the machine enters the memory and read-out modes, only the SAVE key, LOAD key,
and ENTER key can be operated. To exit the mode, press the LOAD key [17] if it is in the
memory mode and the SAVE key [18] if in the read-out mode. Memory can be copied to a
different condition number after reading the welding conditions you want to copy.
Note:
Even when welding conditions are read out while the analog remote control is
connected to the welding power source, the setting values preset at the analog remote
control are valid.
Ԙ
SAVE Function
Welding conditions being currently in use are stored in the memory inside the welding
power source.
٨
Holding the welding conditions in memory
(1) When pressing the SAVE key [18], the machine enters memory mode, the SAVE
lamp (located at the upper left of the SAVE key) lights up. See the following picture.
In the right display, condition number “1” blinks and the LED lamp of the welding
condition number lights up. In the left display, the setting value of welding current
preset to the condition number "1" is displayed. Under this condition, a condition
number can be set while turning the parameter adjusting knob [4].
Welding Current setting value
Condition number blinks
held in memory
In the event that any memory data is already preset to the condition number you
selected, the CRATER lamp, the WELDING METHOD lamp, etc. also light up. If no
memory data is preset to the condition number you selected, “- - -” in the left
display blinks. In this case, the system skips the parameter check condition of Step
(2) and jumps to Step (3).
WARNING
A
%
JOB
NO.
Se
Hz
WARNING
A
%
JOB
NO.
Se
Hz