33
CONDITION
CHECK
Check continuity of magnetron
Defective mag-
netron
RESULT
No
Continuity
CAUSE
REMEDY
Replace
Outlet has
proper volt-
age Fuse
does not
blow.
CONDITION
CHECK
Check continuity of primary inter-
lock switch
Malfunction of pri-
mary interlock
switch
RESULT
No
Continuity
CAUSE
REMEDY
Adjust or
replace
Turn table
motor and
oven lamp
do not turn
on
Check continuity of secondary
interlock switch
Malfunction of sec-
ondary interlock
switch
No
Continuity
Adjust or
replace
Check D.C. voltage being sup-
plied to RELAY (RY2) coil
Defective touch
control circuit
0 V
Replace
Faulty contacts of
RELAY (RY2) or
open relay coil
Approx.
15 VDC
Replace
Display do not shown
countdown
Malfunction of sec-
ondary interlock
switch
Replace
Check continuity of
power supply cord
Open power sup-
ply cord
No
Continuity
Replace
Defective touch
control circuit
Normal
Replace
NOTE 1
All these switches must be replaced at the same time, please refer to “Interlock Mechanism And Adjustment”.
(TROUBLE 2) Display shows all figures selected, but oven does not start cooking, even though
desired program and time are set and start pad is tapped.
Summary of Contents for KOT-170S0A
Page 8: ...7 FIG 1...
Page 22: ...21 FIG 13 1 FIG 13 2...
Page 42: ...41 WIRING DIAGRAM 1 WIRING DIAGRAM...
Page 56: ...55 3 PRINTED CIRCUIT BOARD FILM MP1 MP3 MP2...
Page 57: ...56...
Page 58: ...57 4 PCB CIRCUIT DIAGRAM...
Page 66: ...65 3 TOTAL ASSEMBLY...