40
COMPONET
TEST PROCEDURE
RESULT
High Voltage Capacitor
Vent Motor Capacitor
High Voltage Diode
Terminal-To-Terminal
Set the ohmmeter to the Rx10k
scale, and measure the resistance
across the capacitor terminals.
Terminal-To-Case
Set the ohmmeter to the Rx1
scale, and measure the resistance
between each terminal and the
case.
Terminal-To-Terminal
Set the ohmmeter to the Rx10k
scale, and measure the resistance
across the capacitor terminals.
Forward Continuity
Set the ohmmeter to the Rx1
scale, and measure forward
resistance across the rectifier
terminals with the (+) lead touching
the anode and the (–) lead touching
the cathode.
a) Normal - The meter
indicates several
ohms, then gradually
returns to infinity.
b) Abnormal - The
meter indicates
infinity, or zero ohms
(a short) immediately.
a) Normal - The meter
indicates infinity.
b) Abnormal - The
meter indicates zero
ohms, or a short.
a) Normal - The meter
indicates several
ohms, then
gradually returns to
infinity
b) Abnormal - The
meter indicates
infinity, or zero ohms
(a short)
immediately.
a) Normal - The meter
indicates several
ohms.
b) Abnormal - The
meter indicates
continuity, or zero
ohms (a short).