15
-MAKING ADJUSTMENTS
Refer to FIG. 7-1 for the following steps:
1. If necessary, adjust the interlock switch housing so that the switches operate properly.
2. Mount the control panel to the oven with the screw you removed earlier.
3. Mount the vent grille to the microwave oven and check out the operation of the switches.
WARNING :
The interlock Monitor Switch provides an added safety check on the Primary and Secondary Interlock Switches.
If the Primary and Secondary Interlock Switches allow the oven to operate with the door open, the Monitor
Interlock Switch will blow the line fuse.
NOTE :
Interlock switch replacement
Whenever safty interlock switches are replaced:
Refer to the following diagram.
Check the connection of monitor switch after replacement.
Perform the electrical continuity check of interlock switches and microwave emission test mentioned in this manual.