23
CONDITION
CHECK
RESULT
Continuity
Continuity in
backward
direction
0 Ω
or
¡Ä
No
Continuity
No
Continuity
0 V
Approx
15 VDC
CAUSE
Defective
high voltage
transformer
Defective
high voltage
rectifier
Defective
magnetron
Defective
magnetron
Defective
high voltage
transformer
Defective
high voltage
transformer
Defective
touch control
circuit
Faulty
contacts of
RELAY
(RY1) or open
relay coil
REMEDY
Replace
Replace
Replace
Replace
Replace
Replace
Replace
Replace
No microwave
oscillation
Check continuity of high
voltage rectifier in
forward and backward
direction with DC
megger
Check continuity of high
voltage capacitor
terminals with wires
removed
Connect megger leads to
magnetron terminal and
magnetron body
Check resistance of
primary and secondary
coil of high voltage
transformer
Check continuity of
magnetron with wires
removed
Check continuity of
filament terminal of high
voltage transformer
Check D.C. voltage
being supplied to
RELAY (RY1) coil
Continuity
TROUBLE SHOOTING GUIDE
(
TROUBLE 3 )
No microwave oscillation even though fan motor rotates.
Summary of Contents for KOR-131G0A
Page 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION ...
Page 29: ...28 WIRING DIAGRAM ...
Page 31: ...30 MP1 MP2 PRINTED CIRCUIT BOARD Measure Point ...
Page 33: ...32 PRINTED CIRCUIT BOARD 2 P C B CIRCUIT DIAGRAM ...
Page 37: ...36 PRINTED CIRCUIT BOARD PRINTED CIRCUIT BOARD MP1 MP2 MP3 Measure Point ...
Page 40: ...39 PRINTED CIRCUIT BOARD 2 PCB CIRCUIT DIAGRAM ...
Page 46: ...45 EXPLODED VIEW AND PARTS LIST 2 KOR 131H4 and KOR 131G4 ...