38
PRINTED CIRCUIT BOARD
6. When Er01 & Er03 come on display.
¡æ
Refer to circuit diagram (Point 6)
- Check method
*
In AUTO REHEATING just operating, checking point A, B, C & D after 1~2 minutes.
*
R20~24 & connecting status of humidity sensor must be checked before checking point A, B, C & D.
7. When the oven is plugged in or during operation, the display does not turn on.
¡
æ
Refer to Circuit diagram (Point 7)
- Check method
NO
CHECK POINT
REMARK
Tolerance
1
A
0.5V
¡
Â
VALUE
¡
Â
3.5V
-
2
B
11.3Vdc
¡
¾
5%
3
C
4.4Vdc
¡
¾
5%
4
D
2.2Vdc
¡
¾
5%
POINT
WAVE FORM
A
+5VDC
B
+10.8VDC(
¡
¾
1V
)