7) Et error
- Cause : Level switch abnormal. ( No pulse is sensed for some time. )
- Control : By time. ( Supply mode is skipped. )
8) Eg error
- Cause : When Ice sensor temperature ( 5 minutes after water supply ) doesn't go up.
- Check point : Ice sensor or water supply line.
9) EA error
- Cause : When sensing ice drop 3 times in level sensor switch error.
- Control : Stop ice maker
- After 1 time rotation EA error code disappear if level swtich is normal.
10) Eu error
- Cause : Sensor which senses if ice is full or not is abnormal.
- Control : When drops the ice, the motor rotates 90 degree.
FUNCTIONS ( Error Display )
11) C1 error
- Cause : When compressor works for over 3 hours although Defrost sensor is over -5C.
- Check point : Refrigerant leakage.
12) F3 error
- Cause : in case defrosting mode ends after 60 minutes.
- Check point : Measure the resistance between both terminals of the defrost heater.
If the resistance is infinity (disconnection) or 0 ohm (short).
17
Summary of Contents for FRX-623B Series
Page 1: ...FPX6034501...
Page 4: ...2 Outside Diemension SPECIFICATIONS The real features are model dependent 3...
Page 24: ...WIRING DIAGRAM Basic Model 23...
Page 25: ...WIRING DIAGRAM Full Models 24...
Page 26: ...WIRING DIAGRAM Full Models_Inverter Comp 25...
Page 32: ...Evaporator in detail How to Disassemble Assemble for each part 31...
Page 34: ...7 Refrigerator Damper changing method How to Disassemble Assemble for each part 33...
Page 39: ...HOW TO Disassemble Assemble for each part 38...
Page 41: ...2 Freezing or cooling failure Weak cooling TROUBLE SHOOTING 40...
Page 44: ...6 Dews on Refrigerator Compartment TROUBLE SHOOTING 43...
Page 45: ...5 Refrigeration failure Foods does not get cool or cold soon TROUBLE SHOOTING 44...
Page 57: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 56...