3. Fan voltage per control mode
Exerted fan motor voltage
1) Normal control : Slow operation mode with relatively low noise level.
2) Load mode : Operation mode which need to be operated by temperature rise at inner side of
refrigerator according to operating condition.
4. Load mode
1) Purpose : To recover temperature rise inside of refrigerator as quickly as possible by load or frequent door opening.
FUNCTIONS ( Fan Control )
Super Freezer mode
13 V
13 V
Normal mode
10 V
13 V
Mode
F-Fan
C-Fan
Load mode /
4 hours after defrosting
/
RT >= 38C
13 V
13 V
2) Operating condition
- When door opening time is more than 1 minutes per 1 time -> Frz. / Ref. go to load mode.
- When sensing more than R/S On Point + 5deg : Ref. load response.
- When sensing more than F/S On Point + 5deg : Frz. load response.
3) Conditions for inactive load response mode.
- When there is no door opening signal during and after defrost cycle, load response mode is inactive.
4) Terminate condition
- After 20 mintues.
- When Ref. sensor reaches to off point, Ref. load mode ends.
- When Frz. sensor reaches to off point, Frz. load mode ends.
11
Summary of Contents for FRX-623B Series
Page 1: ...FPX6034501...
Page 4: ...2 Outside Diemension SPECIFICATIONS The real features are model dependent 3...
Page 24: ...WIRING DIAGRAM Basic Model 23...
Page 25: ...WIRING DIAGRAM Full Models 24...
Page 26: ...WIRING DIAGRAM Full Models_Inverter Comp 25...
Page 32: ...Evaporator in detail How to Disassemble Assemble for each part 31...
Page 34: ...7 Refrigerator Damper changing method How to Disassemble Assemble for each part 33...
Page 39: ...HOW TO Disassemble Assemble for each part 38...
Page 41: ...2 Freezing or cooling failure Weak cooling TROUBLE SHOOTING 40...
Page 44: ...6 Dews on Refrigerator Compartment TROUBLE SHOOTING 43...
Page 45: ...5 Refrigeration failure Foods does not get cool or cold soon TROUBLE SHOOTING 44...
Page 57: ...COOLING CYCLE HEAVY REPAIR Brzing Reference Drawings 56...