22
OPERATION AND FUNCTION
13. Demonstration Function
INPUT
CONTROL OBJECT
1. Door Switch
2. TEMP Control Button
1. Electric Devices
CONTENTS
REMARK
1. Start : open and close Refrigerator[Freshfood Compartment] Door 5 times
while pushing TEMP Control Button at the same time.
2. Control
1)
Electric devices turn Off except for F-Fan.
2)
Fan Control
Door Open
Door Close
F-FAN
ON
OFF
3. Dissolution :
1)
Open and close Refrigerator[Freshfood Compartment] Door 5 times
while pushing TEMP Control Button at the same time
in Demonstration mode.
2)
Supply the power again(plug-out and plug-in)
14. Control of R-Sensor Off-Point
INPUT
CONTROL OBJECT
1. Slide SW(SW1) on M-PCB
1. Control Resistance of R-Sensor “2” Off-point
CONTENTS
REMARK
1. In case of Weak-refrigeration (though F-Fan and COMP work on and on), the
following actions are to be done.
2. Resistance R70 : Control Resistance of R-Sensor Medium Off-point
( 4.0
B
C ,
31.4K
Ω
)
3. Resistance R71 : reduceing R-Sensor Resistance by 1.5
B
C
Refrigeration (2.5
B
C ,
2K
Ω )
4. Resistance R72 : reduceing R-Sensor Resistance by 1.5
B
C
in case of weak-
Refrigeration (1.0
B
C , 2K
Ω )
5. J1,J2 : during A/S, if J1,J2 are opened, R-Sensor Medium Off-point
decreases by 1.5
B
C
6. J1,J2 Status and R-Sensor Medium Off-point
J1,J2 Status
R-Sensor Medium Off-point
J1 (o), J2 (o) 4.0
B
C
J1 (x), J2 (o) 2.5
B
C
J1 (x), J2 (x) 1.0
B
C
- (o) : Jumper exist
- (x) : Jumper
don’t exist
Summary of Contents for FR - 530NT
Page 3: ...1 EXTERNAL SIZE á FR 530NT á FR 590NT 1 EXTERNAL VIEWS 2 ...
Page 4: ... á FR 590NW EXTERNAL VIEWS 3 ...
Page 24: ...1 WIRING DIAGRAM 4 DIAGRAM 23 ...
Page 26: ...3 AIR FLOW DIAGRAM DIAGRAM 25 ...
Page 40: ...6 1 FR 530NT FR 590NT TOTAL EXPLODED VIEW 6 EXPLODED VIEW AND PARTS LIST 39 ...
Page 45: ...6 2 FR 590NW TOTAL EXPLODED VIEW EXPLODED VIEW AND PARTS LIST 44 ...