Dissolution : if R -Sensor is in normal state, it is finished by
itself.
2) “rt” Error
Occurrence : RT -Sensor open /short-circuit
Control : deletion of control-condition by RT-Sensor
Dissolution : if RT -Sensor is in normal state, it is finished
by itself.
3) “d1” Error
Occurrence : D-Sensor open /short-circuit
Control : by limit time(40min.) of Defrosting-return
Dissolution : if D -Sensor is in normal state, it is finished
by itself.
4) “door” Error
Occurrence : when door-opening is sensed for more than 1
hour
Control : deletion of Door SW sensing function
Dissolution : if Door SW open -close is sensed, it ends by
itself.
Display dissolution : after Custom LED Display Mode
(Door SW should be in normal state if Error Display Mode
is to start.)
6) “C1” Error
Occurrence : when COMP runs continuously for more than
3 hours while D-Sensor is above -5
Control : normal running
Dissolution : when D-Sensor temperature is below -5
while Comp is Off
7) “F3” Error
Occurrence: by limit time of 80min
at defrosting- return
Control :
normal running
Dissolution
: the end of defrosting is done
by D- Sensor
OPERATION AND FUNCTION
Summary of Contents for FR - 530NT
Page 3: ...1 EXTERNAL SIZE á FR 530NT á FR 590NT 1 EXTERNAL VIEWS 2 ...
Page 4: ... á FR 590NW EXTERNAL VIEWS 3 ...
Page 24: ...1 WIRING DIAGRAM 4 DIAGRAM 23 ...
Page 26: ...3 AIR FLOW DIAGRAM DIAGRAM 25 ...
Page 40: ...6 1 FR 530NT FR 590NT TOTAL EXPLODED VIEW 6 EXPLODED VIEW AND PARTS LIST 39 ...
Page 45: ...6 2 FR 590NW TOTAL EXPLODED VIEW EXPLODED VIEW AND PARTS LIST 44 ...