OPERATION AND FUNCTION
9. Initial Defrosting
INPUT
CONTROL OBJECT
1. D-Sensor
2. Initial Power Supply
1. Defrosting Mode
CONTENTS
REMARK
1. Defrosting mode starts when D-Sensor
[
3.5
B
C at initial power supply.
(It starts from Pre-cool.)
COMP delayed for
6min. at initial
defrosting
10. Explanation after Delivery
INPUT
CONTROL OBJECT
1. TEMP Control Button
2. Power Cord
1. Electric Devices
CONTENTS
REMARK
1. Start : push the TEMP Control Button for 5 seconds within 10sec
after initial power supply(plug-in).
2. Electric devices turn Off for 3 hours.
3. Display works in normal way.
11. Prevention of COMP Restart
INPUT
CONTROL OBJECT
1. (None)
1. COMP
CONTENTS
REMARK
1. COMP does not restart for 6 minutes after COMP Off, though R-Sensor
turns On.
6 min. delay
12. Buzzer Alarm
INPUT
CONTROL OBJECT
1. Buttons on F-PCB
2. Door Switch
1. BUZZER
CONTENTS
REMARK
1. Buzzer rings by pushing F-PCB Buttons.
2. Buzzer rings for 1 second after initial power supply (plug-in).
3. Buzzer rings for 1 second at the start of A/S Forced Defrosting.
4. Buzzer rings every 1 minute after door opening.
(It rings within 5minutes and ring-time is prolonged as time passes.)
5.
Buzzer makes short ring every 5 seconds in Error Display.
Summary of Contents for FR - 530NT
Page 3: ...1 EXTERNAL SIZE á FR 530NT á FR 590NT 1 EXTERNAL VIEWS 2 ...
Page 4: ... á FR 590NW EXTERNAL VIEWS 3 ...
Page 24: ...1 WIRING DIAGRAM 4 DIAGRAM 23 ...
Page 26: ...3 AIR FLOW DIAGRAM DIAGRAM 25 ...
Page 40: ...6 1 FR 530NT FR 590NT TOTAL EXPLODED VIEW 6 EXPLODED VIEW AND PARTS LIST 39 ...
Page 45: ...6 2 FR 590NW TOTAL EXPLODED VIEW EXPLODED VIEW AND PARTS LIST 44 ...