16
OPERATION AND FUNCTION
5. Defrosting Mode
INPUT
CONTROL OBJECT
1. Defrosting Period
1. COMP
2. F-FAN
3. HEATER
CONTENTS
REMARK
1. Defrosting Mode
1)
Time : 25minutes
2)
COMP and F-Fan are On,
and HTR is off
3) Pre-cool turns off when R-Sensor
[
2.5
B
C
1)
Heater turns off when D-Sensor
[
10
B
C
2)
Limit time : 80minutes
3)
Heater continues to be On for 40 minutes of
limit time when D-Sensor is in error.
4)
Limit time
j
30seconds: Heater continues to be
k
On after Defrosting regardless of
l
D-Sensor temperature.
m
40minutes: in case of D1-Error
n
80minutes: in normal control state
1)
Time : 4minutes
2)
COMP and F-Fan are Off.
1)
Time : 5minutes
2)
Only COMP is On, while F-Fan is Off.
2. Output Control and Limit Time of each Defrosting Mode
Pre-cool
HTR Defrosting
Pause
Fan-
delay
COMP
ON
OFF
OFF
ON
F-Fan
ON
OFF
OFF
OFF
Heater
OFF
ON
OFF
OFF
Limit
Time
25 min
j
80 min
k
40 min
(In D-Sensor error)
4 min
5 min
C-Fan and COMP are
co-working.
Pre-cool
Heater Defrosting
Pause
Fan-delay
Summary of Contents for FR - 530NT
Page 3: ...1 EXTERNAL SIZE á FR 530NT á FR 590NT 1 EXTERNAL VIEWS 2 ...
Page 4: ... á FR 590NW EXTERNAL VIEWS 3 ...
Page 24: ...1 WIRING DIAGRAM 4 DIAGRAM 23 ...
Page 26: ...3 AIR FLOW DIAGRAM DIAGRAM 25 ...
Page 40: ...6 1 FR 530NT FR 590NT TOTAL EXPLODED VIEW 6 EXPLODED VIEW AND PARTS LIST 39 ...
Page 45: ...6 2 FR 590NW TOTAL EXPLODED VIEW EXPLODED VIEW AND PARTS LIST 44 ...