2
BUTTON
ADJUSTMENT
‚
Forced Defrost Mode : Start by pressing CONTROL button for 5 seconds
continuously.
ƒ
SHORT CIRCUIT TEST : start and cancel by pressing CONTROL button 30 times
continuously.
2) FUZZY BUTTON
•
Press the FUZZY button to turn on & off.
3) TEMP. BUTTON
•
If you press ‘TEMP’ button one time, it displays the temperature of Room R. If you
press ‘TEMP’ button two times continuously, it displays the temperature of Room
F.
3
TEMPERATUR
E
ADJUSTMENT
&
CONTROL
1) TEMP. CONTROL BUTTON
•
COMP. will be controlled by ON / OFF point of each mode.
k
STEP DIFF of ROOM R:
Ÿ
VAC ~ 4
→
1deg
Ÿ
4~ TURBO
→
1.5 deg
l
ROOM R MIDDLE OFF point : -1.0°C (7 STEPS)
m
ON/OFF DIFF. of ROOM R :
- DEFAULT MODE
&
ENERGY CONSUMPTION MODE
: 5 deg
- LOW RT & HIGH RT : DEFAULT MODE : 4 deg
2) FORCED DEFROST
•
FORCED Defrost mode will be Started independent of the cycle.
k
The flow is same as the general defrost mode flow.
3) SHORT CIRCUIT OPERATION
•
COMP & FAN will be on independent of the operation condition.
k
The time limit of SHORT CIRCUIT OPERATION : 60 hrs
51
Daewoo Electronics
Summary of Contents for ERF-36.A..EU
Page 12: ...8 MAIN PCB DIAGRAMS 8 1 ERF 364A EU ERF 384A EU ERF 394A EU ERF 414A EU Daewoo Electronics 12...
Page 13: ...8 2 ERF 367A EU ERF 387A EU ERF 397A EU ERF 417A EU 13 Daewoo Electronics...
Page 14: ...8 3 ERF 364AR ERF 384AR ERF 394AR ERF 414AR Daewoo Electronics 14...
Page 15: ...8 4 ERF 367AR ERF 387AR ERF 397AR ERF 417AR 15 Daewoo Electronics...
Page 26: ...11 EXPLODE DRAWINGS 11 1 ERF 364AR ERF 394AR ERF 414AR Daewoo Electronics 26...
Page 27: ...27 Daewoo Electronics...
Page 30: ...11 2 ERF 367AR ERF 397AR ERF 417AR Daewoo Electronics 30...
Page 31: ...31 Daewoo Electronics...
Page 34: ...11 3 ERF 384AR Daewoo Electronics 34...
Page 35: ...35 Daewoo Electronics...
Page 38: ...11 4 ERF 387AR Daewoo Electronics 38...
Page 39: ...39 Daewoo Electronics...