8
DEFROST
MODE
1) General Defrost Mode
•
Start : By determination of defrost
k
Process : general operation - Heater on - Pause - general operation
R-134A
R-600A
TEMP. of Defr ost return
10°C
16°C
PAUSE TIME
6min
7min
On D-sensor Error
30min
60min
Limit time
80min
80min
2) Forced Defrost Mode
•
Start : by press TEMP. CONTROL button for 5 seconds continuously.
k
Process : same as General Defrost Mode
General Defrost Mode is on for initial 30 seconds after heater is on. (for TEST)
9
INITIAL
DEFROST
1) When power is on, if the temperature at the D-sensor is under 3.5°C, then General
Defrost Mode starts.
10
PREVENTION
OF COMP.
RESTART
1) RT
≤
17 : The COMP can’t be on within 40 min after comp. is off even though
R-sensor is on condition. (This is to protect comp.) - FUNCTION of LOW RT
2) RT > 8 : The COMP can’t be on within 6 min after comp. is off even though
R-sensor is on condition. (This is to protect comp.)
11
ERROR
DISPLAY
&
CONTROL
1) D1 ERROR (It happens when D-SENSOR is OPEN or SHORT)
•
DISPLAY : FREEZER RED LED lamp in on & off one time.
k
CONTROL : Return to the limit defrost time of Defrost (30 min)
2) D2 ERROR (It happens when heater is off by time (80 min).
•
DISPLAY : FREEZER RED LED lamp in on & off two times.
k
CONTROL : Return to the limit defrost time of Defrost (80 min)
3) R1 ERROR (It happens when R-SENSOR is OPEN or SHORT)
•
DISPLAY : REFRIGERATOR RED LED lamp in on & off one time.
k
CONTROL : controlled by the condition of RT
RT-S TEMP
ERROR
24
-
-
18
-
-
COMP. Operating rate (%)
40%
30%
44%
ON/OFF (min)
20 / 30
15 / 35
22 / 28
NOTE
ERROR
Low RT TEMP.
General
l
CANCEL : when R-SENSOR is working normally.
4) RT ERROR (It happens when RT -SENSOR is OPEN or SHORT)
•
DISPLAY : REFRIGERATOR RED LED lamp in on & off two times.
k
CONTROL : The system is normally operating but the controlling by RT-
SENSOR doesn’t work.
l
CANCELATION : when RT -SENSOR is working normally.
47
Daewoo Electronics
Summary of Contents for ERF-36.A..EU
Page 12: ...8 MAIN PCB DIAGRAMS 8 1 ERF 364A EU ERF 384A EU ERF 394A EU ERF 414A EU Daewoo Electronics 12...
Page 13: ...8 2 ERF 367A EU ERF 387A EU ERF 397A EU ERF 417A EU 13 Daewoo Electronics...
Page 14: ...8 3 ERF 364AR ERF 384AR ERF 394AR ERF 414AR Daewoo Electronics 14...
Page 15: ...8 4 ERF 367AR ERF 387AR ERF 397AR ERF 417AR 15 Daewoo Electronics...
Page 26: ...11 EXPLODE DRAWINGS 11 1 ERF 364AR ERF 394AR ERF 414AR Daewoo Electronics 26...
Page 27: ...27 Daewoo Electronics...
Page 30: ...11 2 ERF 367AR ERF 397AR ERF 417AR Daewoo Electronics 30...
Page 31: ...31 Daewoo Electronics...
Page 34: ...11 3 ERF 384AR Daewoo Electronics 34...
Page 35: ...35 Daewoo Electronics...
Page 38: ...11 4 ERF 387AR Daewoo Electronics 38...
Page 39: ...39 Daewoo Electronics...