background image

2

0

 

 Washing Heater isn't reworking after reach decision temperature.

 

 Normal 40°C include 7 min that heater does not working.

 

 If Set up 40°C then main washing time is 40 min.

 

 If LS value is more than 360, 1 hour add in Washing Time.

 

3) Electric Current Time of Washing Motor

 

 It works decision cycle

 

 If Motor Restriction occur by overload, Motor try to rework opposite direction.

 

 While Water Supply, Motor Stir proceed ON first.

 

 Crease Care is process of removal laundry that stick to drum. It works after Spin Sequence. 

 

  Electric Current Time of Washing Motor ON/OFF Time is finishing washing of Steam White and 

Baby Courese.

 

  Each Time of Electric Current Time of Washing Motor of Steam White and Baby Course is 10/5, 

18/6. 

4) Re-Water Supply 
 

 It works if water level is lower than decision level

 

 Motor stopped while Re-Water Supply

 

 While Wash Sequence Re-Water Supply works 15 times.

 

 If Water Level is lower than RESET Level, Display IE and Heater off.

                             Part 

Course

Water 

Temperature

MOTOR TIME On/OFFF(sec)

Speed

Water

Supply

Washing

Soak

Crease

Care

Heating

Main Washing

Cotton/Normal

5/10

10/10

18/6

15/180

10/5

45 r.p.m

Synthetic

5/10

10/10

18/6

15/180

10/5

45 r.p.m

Delicate/Hand Wash

X

X

3/30

15/180

X

45 r.p.m

Intensive

5/10

10/10

10/5

15/180

10/50

45 r.p.m

Quick20

5/10

X

10/5

15/180

10/50

45 r.p.m

Sports Wear

5/10

10/10

15/6

15/180

10/50

45 r.p.m

Tun Clean

5/10

X

10/30

15/180

10/50

45 r.p.m

Drain

-

-

-

-

-

-

Summary of Contents for DWC-1011W

Page 1: ...Service Manual Model DWC 1011W Drum Washing Machine April 2010 ...

Page 2: ...ACHINE SERVICEMANUAL 1 WHAT IS DRUM WASHING MACHINE 1 2 Washer Specification 3 3 Parts list by ass y 4 4 Control Part Function Specification 17 5 Electronic Field Parts List and Specification 32 6 Wiring Diagram 33 ...

Page 3: ...st andthemostcomfortable angleejectintothelaundryisconvenientandeasyto manipulate StarDrum UsingStarDrumisabletohigherWashing PerformanceandMinimaldamageoflaundry water consumption LuxuryAudioDial UsingtheadvancedAudioDialisluxurydesignof exterior DDinvertermotor Thedirect drivetypeofwhichmotorisdirectly connectedtodrumwithoutaninterimchuth significantlyreducesnoiseandvibration Self CleaningCourse...

Page 4: ...2 DD Control Direct drive type of direct connection between drum and motor Rotation by powerful high performance BLDC motor 3 Power System Pump Drainage BLDC LAUNDRY ...

Page 5: ...D1411 1611 Dimension mm 600 X 645 X 850 Maximum mass of textile kg 9 Kg Unit Weight net gross 78 82 71 75 76 80 69 73 Standard Water Consumption 65 ℓ Spin Speed RPM DWC DWD LU10XX MAX 1000 DWC DWD LU12XX MAX 1200 DWC DWD LD14XX MAX 1400 DWC DWD LD16XX MAX 1600 Operating Water Pressure 0 03MPa 0 8MPa 0 3kgf cm2 8kgf cm2 ...

Page 6: ...4 2 PANEL F AS A01 A02 A03 A04 A09 A10 A11 A12 A13 A07 A06 A14 A18 A17 A16 A15 A08 A05 Panel Front Parts List ...

Page 7: ...DISPLAY 3613058600 ABS 1 A07 CASE PCB F 36111T1R00 HIPS 1 A08 SCREW TAPPING 7122401611 T2S TRS 1 4x16 MFZN A09 PCB BOARD F 3614348500 FR 1 1 A10 HOLDER LED COURSE 3613058400 HIPS 1 A11 BUTTON DIAL 3616644300 ABS 1 A12 DECORATOR BUTTON DIAL 3611696400 ABS 1 CHROMIUM CILDING A13 BUTTON START 3616644600 ABS 1 A14 BUTTON POWER 3616644500 ABS 1 A15 DECORATOR FILM 36116 P C FILM 1 A16 WINDOW COURSE 3615...

Page 8: ...6 B01 B02 B03 B05 B04 B08 B07 B06 B10 B09 B11 B12 B13 B14 3 INLET BOX AS ...

Page 9: ...0 240V VDE BITRON 1 B07 HOSE WATER SUPPLY 3613270900 EPDM ID9 5 OD14 5 WASHING 1 B08 HOSE WATER SUPPLY 3613270900 EPDM ID9 5 OD14 5 PRE WASH 2 B09 CLAMP HOSE 3611205800 100H ID 13 8 W 10 0 0 9T 10 B10 VALVE INLET 3615414820 220 240V 1 WAY HOT PP 1 B11 HOSE WATER SUPPLY 3613270900 EPDM ID9 5 OD14 5 HOT 1 B12 HOSE WATER SUPPLY 3613270900 EPDM ID9 5 OD14 5 STEAM 1 B13 PIPE JOINT I 3614426000 PP 1 B14...

Page 10: ...8 5 DOOR AS C11 C01 C02 C03 C12 C10 C09 C04 C07 C05 C06 C08 2st Model ...

Page 11: ...A113300 GLASS 1 C04 FRAME DOOR 1 36122UDD00 PP 1 C05 HINGE DOOR 3612903800 ALDC 1 C06 CAP HINGE DOOR 3610916500 POM 4 C07 SCREW TAPPING 7115402029 T1S FLT 14 4 20 STS430 NATURE C08 HOOK DOOR 3613100900 ZNDC 1 C09 SPRING HOOK 3615115400 SUS 1 C10 KOOK SHAFT 36131101000 SUS 1 C11 CASE SPRING DOOR 3611149300 ABS 1 C12 SCREW TAPPING 7122401611 T2STRS 2 4 6 MFZN ...

Page 12: ... TUB ASSY DD MOTOR D26 D23 D22 D25 D24 D20 D18 D17 D19 D16 D15 D10 D21 D11 D04 D07 D05 D06 D08 D03 D01 D02 D39 D42 D34 D41 D43 D32 D31 D33 D36 D28 D30 D27 D29 D09 D13 D14 D12 D40 D38 D37 D35 D44 D45 D46 D47 ...

Page 13: ...3 YW D2 6 ID36 W44 5 1 D15 AIR TRAP 361A500101 PP 1 D16 HOSE AIR PRESSURE 3613266930 ID 4 OD 8 L 680MM L SERIES 1 D17 DAMPER FRICTION 361A700110 70N AKS ST 170 260 DL 197 5 LOW NOISE 2 D18 DAMPER PIN 361A700200 AKS D 14 5 2 D19 TUB FRONT 3618830000 FRPP C LU1011 1 D20 SPRING SUSPENSION 3615116800 KGF 2 D21 SPECIAL SCREW 3616029800 SWCH 6 5X30 14 D22 SPECIAL SCREW 3616029500 SUS430 8 25 3 D23 LIFTE...

Page 14: ...OPTION D39 UNIT BUBBLE GENERATOR 36189L4177 HIGH PAD B BL WH 320 RP4 GUIDE O SPONGE 200 1 OPTION D40 HOSE VENT 3613267100 EPDM 1 D41 BEARING OUTER 3616303200 6205Z 1 D42 HEATER WASH 3612803700 230V 2000W 1R5A721002 IRCA FUSE 2EA 1 D43 PIPE DUCT AS 3614414001 C L PIPE DUCT HOSE CLAMP 1 D44 UNIT STATOR BLDC 36189L6200 AL 30T 28T NMT 1 D45 SPECIAL BOLT AS 3616029900 SWCH M8 SILOCK 6 D46 UNIT ROTOR BL...

Page 15: ...13 8 DUCT B E01 E15 E13 E14 E12 E11 E04 E07 E06 E10 E08 E03 E05 E02 E09 ...

Page 16: ...0 C OFF150 C 230V 15A VDE 1 E06 DUCT B LOWER 361A202500 ALDC C LU1011 1 E07 BUSHING UPPER 3610703800 POM C LU1011 4 E08 BUSHING LOWER 3610703900 POM C LU1011 4 E09 GASKET SEAL A 3612325700 EPDM FOAM D 5 L 1293 1 E10 PACKING RUBBER 3614009800 SILICON DWD 100DR 1 E10 THERMISTOR DRY 361AAAAD00 C LD LU L 200 R40 26 065K R90 4 4278K 1 E11 NUT HEX 3616032100 M6 1 0P CCW 1 E12 FAN AS 3611886400 GFPP30 C ...

Page 17: ...15 9 CABINET AS F07 F01 F03 F02 F04 F05 F10 F09 F08 F06 F11 F12 F13 ...

Page 18: ... T2 0 1 F05 LEG ADJUST AS 3617703811 CHINA PARTS DWD 900W 4 F06 MAIN PCB AS 3610PCBL00 D LU1212EFA 1 F07 PLATE T 3614541100 SECC 1 2T C LU1011 1 F08 SENSOR PRESSURE 3614825240 DL DW13 AIR INLET 315 1 F09 COVER B 3611431600 0 4T SGCC C LU1011 1 F10 FIXTURE TUB AS 3612007421 6KG CHINA SAMWOO 4 F11 FRAME UPPER 36122UD900 SGCC 1 2T 1 F12 UNIT DRAIN PUMP AS 36189M2T00 AC220 240V 50HZ HANYU AL 30W DUAL ...

Page 19: ... 28min 28min 23min 28min 33min 25min 15min R I N S E Drain 1min Balancing Spin Remove Bubble 2min Mid Spin 4min Water Supply 2min Rinse 1 3min Drain 1min Balancing Spin 2min Mid Spin 4min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 2min Mid Spin 4min Water Supply 2min Rinse 3 3min S P I N Drain 1min Balancing Spin 2min Main Spin 7min 5min 3min END Crease care 1min End 10sec Remain Tim...

Page 20: ...se 1 3min Drain 1min 1min Balancing Spin 2min 1min Mid Spin 4min 2min Water Supply 2min 1min Rinse 2 3min 1min Drain 1min 1min Balancing Spin 2min 1min Mid Spin 4min 2min Water Supply 2min 1min Rinse 3 3min 1min S P I N Drain 1min 1min Balancing Spin 2min 1min Main Spin 7min 5min 30min 2min D R Y Crease care 60sec Drain 1min Dry 100min Add 46min only dry model 30min Cooling 5min End 10sec Crease C...

Page 21: ...X 30min Part Course Water Level HEATING Time Washing Time TotalWashingTime Cotton Normal 30 C Small 10min 28min 38min Middle 15min 28min 43min 40 C Small 15min 28min 43min Middle 20min 28min 48min 60 C Small 30min 28min 58min Middle 35min 28min 63min 90 C Small 60min 28min 88min Middle 70min 28min 98min Synthetic 30 C Small 15min 23min 38min 40 C Small 20min 23min 43min Delicate Hand Wash Small 0m...

Page 22: ...am White and Baby Courese Each Time of Electric Current Time of Washing Motor of Steam White and Baby Course is 10 5 18 6 4 Re Water Supply It works if water level is lower than decision level Motor stopped while Re Water Supply While Wash Sequence Re Water Supply works 15 times If Water Level is lower than RESET Level Display IE and Heater off Part Course Water Temperature MOTOR TIME On OFFF sec ...

Page 23: ... m If it can t R Spin while performanced 20 times pass to next sequence In Shoes Course does not working B Spin part Water Level level height mm KHz etc Mid 225 24 32 Rinse water level part Water Level Water Temp Rinse Time Mid Spin Mid Spin r p m MOTOR On OFF sec rpm water supply rinse Cotton Normal Cold 3min 4min mid 45 r p m 5 10 10 5 Synthetic Cold 3min 4min mid 45 r p m 5 10 10 5 Delicate Han...

Page 24: ...f B Spin to end of Spin Sequence is R Spin r p m is affected by sequence 4 Shoes Spin Balace Spin does not working 2 4 End 1 Crease Care Crease Care is process of removal laundry that stick to drum It works 30sec after Spin Sequence Wool and Shoes course don t work crease care 2 End After 10 sec power off alamed END If drying sequence added work drying sequence After END door unlock ...

Page 25: ...ing time is total 5 min 5 Drying Heater working Drying Heater work until End of Drying Sequence Shoes Course 70 C OFF 60 C ON Air Course 80 C OFF 70 C ON 6 Crease Care Crease Care performance after Drying Sequence for 30 min Only Motor work during Wrinkle Free Drain 1min Drying 144min COOLING 5min End 10sec Crease Care 30min Not Displayed Crease Care Drying COOLING Wrinkle Free Time Heater Off On ...

Page 26: ...ing during balance spin Spreading the laundry Rotating the same 45 rpm with left and right direction alternatively Unbalance checking point first step sheck the U B at 95 rpm 160 rpm second step check the U B at 95 rpm 350 rpm Third step at 300 rpm If the unbalance data is over the criterion This process will be repeated After drain check the unbalance data again This is so called balance spin ste...

Page 27: ...dry during washing press the door unlock button Door open sequence at abnormal condition 3 4 Child Lock Press the Spin and Condensing Dry button simultaneously during processing Under the Child Lock function only power button is working During Child Lock function CHL will be displayed on 18 88 In order to unlock Child Lock mode press Spin and Condensing Dry simultaneously 3 5 The sequence of drain...

Page 28: ...Mas detalles Cuando el dislay regrese a LOCK se oira una señal indicando que concluyó normalmente Al inicio de la prueba de la PCB el displays muestra las condiciones de los sensores En este caso el motor BLDC no se preuba para probarlo seleccione enjuague o exprimido 5 2 Continúa Modo de prueba 1 Procceso Presione y mantenga simultáneamente Temp option SPIN presione POWER Todos los LED enciende p...

Page 29: ...ed off and OE blinks in 18 88 display 3 Error buzzer alarm is sounded for 10 seconds per every 10 minutes 4 Error display is cleared when turning off on power 6 3 UE Unbalance Error 1 Conditions of Occurrence In case main spin drying is not reached within 20 cycles of balance spin drying In case balance spin drying fails during interim spin drying UE occurs as the cycle moves to the next process 2...

Page 30: ...ine test mode 2 Water supply motor is kept on until water level falls below reset 3 All LEDs are turned off and E1 blinks in 18 88 display 4 Error buzzer alarm is sounded for 10 seconds per every 10 minutes 5 Error display is cleared when turning off on power 6 6 E2 Overflow error 1 Conditions of Occurrence In case water level in water tank is above overflow level due to continuous operation of wa...

Page 31: ...for 10 seconds per every 10 minutes 4 Error display is cleared when turning off on power 6 8 E9 Abnormalities in water level sensor 1 Conditions of Occurrence In case water level frequency is of 15KHz or lower and 30KHz or higher during cycle due to abnormalities in water level sensor etc 2 All LEDs are turned off and E9 blinks in 18 88 display 3 Error buzzer alarm is sounded for 10 seconds per ev...

Page 32: ...window Error buzzer alarm is sounded for 10 seconds per every 10 minutes Error display is cleared when turning off on power 4 E8 Initial Operation Fail Error In case input signal of Hall IC is abnormal due to problems in motor connection etc Motor operation is stopped and E8 is shown in display window Error buzzer alarm is sounded for 10 seconds per every 10 minutes Error display is cleared when t...

Page 33: ...emperature is higher than 42 If temperature does not increase by1 or more If temperature falls below standard temperature by 2 or more due to re supply of water etc standard temperature is reset as the current temperature and error check time of15 minutes is reset Error buzzer alarm is sounded for 10 seconds per every 10 minutes Error display is cleared when turning off on power 5 H8 Error Washing...

Page 34: ... New DFC 2710D 250V 10A 50 60HZ 1 9 Unit Steam AS 36189M2U00 New 230V 900W 1 10 Harness AS 3612799A00 New UNIVERSAL_COMBO FULL OPTION 1 3612799B00 DD_COMBO FULL OPTION 3612799C00 UNIVERSAL_WASH FULL OPTION 3612799D00 DD_WASH FULL OPTION 11 Heater Wash 3612803700 Common 230V 2000W 1R5A721002 IRCA FUSE 2EA 1 12 Thermistor Wash 361AAAAB10 Common R25 1 704K R80 11 981K 1 13 Unit Motor Universal 36189L...

Page 35: ...33 6 WiringDiagram DWC LD S 33 ...

Page 36: ...34 DWC LU S ...

Page 37: ...S M No DAEWOO ELECTRONICS CORP 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 cable daewooelec PRINTED DATE Oct 2009 ...

Reviews: