3) H5 Error - Water temperature error in wool/ delicate course
①
In case water temperature in wool/ delicate course is 45
℃
or higher
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
4) H6 Error - Abnormality in washing heater
①
Within 15 minutes after heater operation begins;
In case standard temperature is of 42
℃
or lower: If temperature does not increase by 2
℃
or more In
case standard temperature is higher than 42
℃
: If temperature does not increase by1
℃
or more
②
If temperature falls below standard temperature by 2
℃
or more due to re-supply of water, etc.,
standard temperature is reset as the current temperature and error check time of15 minutes is reset.
③
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④
Error display is cleared when turning off/ on power.
5) H8 Error - Washing heater overheating
①
In case washing heater temperature increases by 5
℃
or more within 30 seconds when there is no
water in tank, etc.
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
Summary of Contents for DWC-1011W
Page 1: ...Service Manual Model DWC 1011W Drum Washing Machine April 2010 ...
Page 8: ...6 B01 B02 B03 B05 B04 B08 B07 B06 B10 B09 B11 B12 B13 B14 3 INLET BOX AS ...
Page 10: ...8 5 DOOR AS C11 C01 C02 C03 C12 C10 C09 C04 C07 C05 C06 C08 2st Model ...
Page 15: ...13 8 DUCT B E01 E15 E13 E14 E12 E11 E04 E07 E06 E10 E08 E03 E05 E02 E09 ...
Page 17: ...15 9 CABINET AS F07 F01 F03 F02 F04 F05 F10 F09 F08 F06 F11 F12 F13 ...
Page 35: ...33 6 WiringDiagram DWC LD S 33 ...
Page 36: ...34 DWC LU S ...