DMB-1812LH(9000BTU/h)
NOTES:
• This appliance must be installed according to National
power supply requirement.
• If the supply cord is damaged, it must be replaced by
the manufacuturer or its service agent or a similarly
qualified person in order to avoid a hazard.
• Make sure the Indoor unit’s AC cord is not connected to
AC power when connecting the indoor/outdoor wire.
• When connecting wires, make sure they are fully insert-
ed and minimum copper wire is exposed. If they are
not, shorting, overheating, no operation, etc. may occur.
• Be sure to comply with local codes on running a wire
from the indoor to the outdoor unit.
2. Fish the indoor/outdoor wire from the rear of the
indoor unit through the front of the unit. For easier
connection, make sure enough wire is pulled through
the front.
Use the wire as shown below:
INSTALLING THE INDOOR/OUTDOOR WIRE TO THE INDOOR UNIT FOR AC CONNECTION
The Indoor/Outdoor wire is used to supply AC from the Indoor unit to the Outdoor unit. To install the indoor/outdoor wire,
follow the procedures below.
3. To connect wires, loosen the screw in the Terminal
Block and insert the correct wires like following figure.
Connect the Brown wire to the “Y” connection,
Yellow/Green wire to the “
” connection and the
Blue wire to “L” connection.
Y
L
Brown
Blue
Yellow/Green
DMB-1812LH
(9000BTU/h)
DMB-1812LH
(9000BTU/h)
Blue
Yellow/Green
Brown
Connection cover
Screw
1. Open the connection cover on the indoor unit to
access the connection area.
Remove the Connection
Cover.
• Loosen the screw fixed at
the Connection Cover.
• Remove the
Connection Cover.
10
Summary of Contents for DMB-1812LH
Page 36: ...36 5 WIRING DIAGRAM ...
Page 47: ...PCBDRIVINGDESCRIPTION ...
Page 48: ...1 PCB CIRCUIT DIAGRAM DMB 1812LH Outdoor ...
Page 49: ......
Page 50: ...DMB 1812LH 12K ...
Page 51: ......
Page 52: ...DMB 1812LH 9K ...
Page 53: ......
Page 77: ...74 6 U9 KIA7042P RESET IC KIA70 42P OUTLINE INPUT GROUND OUTPUT VCC 1 3 2 OUT GND ...
Page 81: ...78 3 EXPLODED DIAGRAM Indoor Unit DMB 1812LH 9K ...
Page 83: ...80 DMB 1812LH 12K ...
Page 86: ...83 4 EXPLODED DIAGRAM Outdoor Unit DMB 1812LH ...
Page 88: ...85 5 CONTROL BOX ASSEMBLY DMB 1812LH 9K ...
Page 90: ...87 DMB 1812LH 12K ...
Page 92: ...89 DMB 1812LH Outdoor ...