17
2-3.2 Motor-driven type start
(1) start
The preparation of moter-driven start type is same as manual type (Recoil type).
CD Open the fuel cock.
® Set the speed governor lever at "start" position.
® Turn on the start switch toward clockwise to "start" position.
© lf the engine is started, take your hand away from key switch immediately.
@ lf the engine do not start after 10 seconds, wait for a while (about 15 seconds) then start again.
(2) Accumulator
CD Check the liquid level in accumulator every month, if the level is lower than the low limit mark,
refill distilled water up to the upper limit mark.
lf the liquid in the accumulator is not enough, the electric motor will not run for too little electric
current. So, keep the liquid level between upper and low limit marks.
The liquid will splash on near parts (which will be spoiled) if it is too much in the accumulator.
Start key Switch
lf the run time of motor is too long, the voltage of accumulator
will drop and the motor may be damaged.
Keep key switch at "ON" position when the engine is running