![DAEWOO ELECTRONICS FRN-U20BC Service Manual Download Page 43](http://html1.mh-extra.com/html/daewoo-electronics/frn-u20bc/frn-u20bc_service-manual_499496043.webp)
42
Change the light bulb.
Start
Repair the F-door switch.
Check the F door switch
connection and F-light socket.
Y
N
N
Y
Change of F Lights
Change of F Door Switch
* Remove 2 screws
of light cover.
* Hold the bottom of light
cover and pull forward
to remove.
* Change the light bulb.
* Insert a flat tip screw
driver Into a gap of door
switch to pull forward.
* Disconnect the housing
and change the switch
for a new one.
①
②
③
①
②
6-2-3. Disconnection / breaking of Freezer Lights Wires
Freezer light filament is
disconnected or breaking ?
Connection of F door
switch is OK ?
※
Be careful when changing
the switch. F and R door
switch are different in type
and shape.
※
Follow the reverse order
of disassembling after
changing the switch.
※
Follow the reverse order
of disassembling after
changing the light.