15
1. A/S Defrosting Mode (Heater defrost
→
Pause
→
Fan Delay)
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
1. Defrosting Cycle
1. Comp
2. F-Fan
3. R-Fan
4. D-Heater
Heater
Defrosting
1) Comp, F-fan, R-fan : OFF
D-HTR : ON
2) Time limit
30 seconds : Heater is ON regardless of D-sensor
temperature right after defrosting start
30 minutes : in case of D1-Error
80 minutes : in normal control state
3) If D-sensor
≥
13
℃
, Heater Defrosting is OFF
Pause
Time : 7 minutes
Comp, F-fan, R-fan, Heater etc. : OFF
Fan-Delay
1) Time : 5 minutes
Comp : ON
F-fan, R-fan, Heater : OFF
Pause
Fan-Delay
Heater
Defrosting
2. How to start
Push “REF.TEMP (Set)” button 5 times while pushing “FRZ.TEMP (Set)” button simultaneously.
3. How to proceed
1) Delete Pre-cool mode. (Others are same as normal defrosting)
2) Heater is ON regardless of D-sensor temp. at first 30 seconds.
(Check of defrosting current)
4-3. (Forced Defrosting) Mode
1. Fan voltage of control mode
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
1. F-Sensor
2. R-Sensor
1. F-FAN, R-FAN, C-FAN
13 V
13 V
13 V
Voltage
C-FAN
R-FAN
F-FAN
FAN
4-4. Fan Voltage of Control Mode
※
Refer to the 5-4. (Fan Function )
Summary of Contents for FRN-U20BC
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 33: ...32 5 WIRING DIAGRAM 5 1 FRS U20IC R 134a R C Type ...
Page 34: ...33 5 2 FRN U20IC R 600a R C Type ...
Page 35: ...34 5 3 FRS U20BC R 134a R C Type ...
Page 36: ...35 5 4 FRN U20BC R 600a R C Type ...
Page 37: ...36 5 5 FRS N U20D E F G R 600a or R 134a R C Type ...
Page 68: ...67 8 5 Dispenser Water Flow ...