13
1. Defrost Mode
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
1. Defrosting Cycle
1. Comp
2. F-Fan
3. R-Fan
4. D-Heater
Pre-Cool
Pause
Fan-Delay
Heater
Defrosting
Pre-Cool
1) Time : 50 minutes
2) Comp , F-fan : ON
R-fan : Control
D-HTR : OFF
3) If F-sensor
≤
-27
℃
, then Pre-Cool becomes. OFF
Heater
Defrosting
1) Comp, F-fan, R-fan : OFF
D-HTR : ON
2) Time limit
30 seconds : Heater is ON regardless of D-sensor
temperature right after defrosting start
30 minutes : in case of D1- Error
80 minutes : in normal control state
3) If D-sensor
≥
13
℃
, Heater Defrosting is OFF
Pause
Time : 7 minutes
Comp, F-fan, R-fan, Heater etc. : OFF
Fan-Delay
Time : 5 minutes
Comp : ON and F-fan, R-fan, Heater : OFF
4-2. Defrost Mode
2.The defrost mode start with the following conditions
1) Total operation time of comp. becomes : 6,8,10,……… 24 hours.
①
Comp. operating rate : more 85%
②
Total door open time : 2 minutes
(Any door, F or R open time is over 2 minutes.)
③
Any error mode : R1, F1, D1, F3, RT/S, Door-switch etc.)
2) Defrosting mode starts unconditionally as long as total comp. work time is
24 hours, even if the above conditions 1) are not satisfied.
3) Defrosting mode starts immediately as long as total time of [comp. ON +
comp. OFF] is over 60 hours, even if the above 1) and 2) conditions are not
satisfied.
3. In providing initial power (or returning power failure)
If D-sensor temp.
≤
3.5
℃
, defrosting mode starts .
Summary of Contents for FRN-U20BC
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 33: ...32 5 WIRING DIAGRAM 5 1 FRS U20IC R 134a R C Type ...
Page 34: ...33 5 2 FRN U20IC R 600a R C Type ...
Page 35: ...34 5 3 FRS U20BC R 134a R C Type ...
Page 36: ...35 5 4 FRN U20BC R 600a R C Type ...
Page 37: ...36 5 5 FRS N U20D E F G R 600a or R 134a R C Type ...
Page 68: ...67 8 5 Dispenser Water Flow ...