22
5. Control way of Errors (if any)
1) “F-sensor” error
Cause : F-sensor open or short
Control : Condition of ambient temperature
How to reset : If F-sensor is normal, the error is terminal temperature.
CONTENTS
REMARKS
2) “R-sensor” error
Cause : R-sensor open or short
Control : Condition of ambient temperature
How to reset : If R-sensor is normal, the error is terminal temperature.
3) “RT-sensor” error
Cause : RT-sensor open or short (full down)
Control : Normal operation, deletion of control by RT-sensor
If RT-sensor is normal, the error is terminated automatically.
4) “D-sensor” error
Cause : D-sensor open or short (full down)
Control : Time limit (30 min) of defrosting return
If D-sensor is normal, the error is terminated automatically.
5) “Door” error
Cause : in case it senses that door is open for more than 1 hour.
Control : Deletion of function related door switch sensing
If door switch (open & close) is sensed, the error is terminated automatically.
6) “Cycle” error
Cause : in case comp. works for over 3 hours when D-sensor temp. is over -5
℃
Control : normal operation
When D-sensor temp. is below -5
℃
in comp. off it is terminated.
7) “Return after defrosting” error
Cause : in case defrosting return is done by time limit of 80 min
Control : Deletion of Pre-cool mode in defrosting mode
If defrosting return is done by D-sensor, it is terminated.
8) A/S forced defrosting mode
Push “REFRIGERATOR SET” button 5 times while pushing “FREEZER SET” button
Simultaneously.
Control : A/S forced defrosting control (Pre-cool is deleted)
If D-sensor temp. is over 10
℃
, the mode is terminated automatically.
When all error code is normal, the Refrigerator reset
35 / 20
35 / 20
26 / 22
27 / 45
16 / 41
14 / 50
ON/OFF (min)
Over 41
℃
~ 41
℃
~ 31
℃
~ 21
℃
~ 15
℃
~ 9
℃
RT-S
6 / 4
4 / 6
3 / 7
2 / 10
3 / 50
OFF
ON/OFF (min)
Over 41
℃
~ 41
℃
~ 31
℃
~ 21
℃
~ 15
℃
~ 9
℃
RT-S
Summary of Contents for FRN-U20BC
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 33: ...32 5 WIRING DIAGRAM 5 1 FRS U20IC R 134a R C Type ...
Page 34: ...33 5 2 FRN U20IC R 600a R C Type ...
Page 35: ...34 5 3 FRS U20BC R 134a R C Type ...
Page 36: ...35 5 4 FRN U20BC R 600a R C Type ...
Page 37: ...36 5 5 FRS N U20D E F G R 600a or R 134a R C Type ...
Page 68: ...67 8 5 Dispenser Water Flow ...