Polaris  1000  User’s  Manual 

Page 7 

1  Introduction 

1.1  General Description 

The Polaris 1000 meter is an electronic kilowatt-hour (kWh) meter that is 

designed for permanent connection to an electrical service. It is designed for single 

phase applications.   

Polaris 1000 meters can be used in 1 phase 2 wire and 1 or 2 phase 3 wire 

configurations.   

1.2  Features 

 

Revenue-grade accuracy 

 

Non-volatile memory, the stored data is maintained through power outages 

 

Use with DAE

’s dedicated split-core CTs (50~600A). Optional solid-core CTs 

available in 50 & 200A. 

 

Parallel up to three sets of CTs for cumulative reading 

1.3  Certifications 

 

UL/CUL Listed 

1.4  Specifications 

Item 

Description 

Frequency 

50/60 Hz 

Working Voltage 

Derived from A phase 

Power Consumption 

7VA 

Measured Parameters 

kWh (default), water meter pulse count (optional)

 

Operating 

Environment 

-20~50

(-4~122

0~95%RH (non-condensing) 

Accuracy 

1

 

0.5% from 1% to 100% of rated load 

Weight 

733g (regular terminal cover) 

690g (

special

 terminal cover 

2

Dimensions 

2

 

W 5” x H 7.42” x D 2.24” wall-mount (regular terminal cover) 

W 5” x H 6.5” x D 2.24” wall-mount (

special

 terminal cover 

2

Based on DAE solid-core CT @ PF=1

 

Please see section 2.5 Conduit and Wire Ingress.

 

 

Summary of Contents for Polaris 1000

Page 1: ...Polaris 1000 User s Manual 2017 11 06 Version 1 3us DAE Instrument Corp http www DAEinstrument com...

Page 2: ...Polaris 1000 User s Manual Page 2...

Page 3: ...p All rights reserved DAE Controls LLC 2707 Golfview Dr 103 Troy Michigan 48084 USA Tel 1 248 635 3708 Fax 1 248 822 8138 e mail info DAEcontrols com DAE Headquarters 5F No 157 Xinhu 1st Road Neihu Di...

Page 4: ...the wiring diagram designated in this manual 6 Guard against dust and water damage 7 Make sure all power sources to be connected to the product have been shut off before installing 8 If the equipment...

Page 5: ...allow air to circulate Reposition any extraneous wiring that is on the Polaris Maintenance Check to make sure that the wiring contacts are tight and making good contact tighten any terminal screws th...

Page 6: ...11 2 3 MOUNTING PROCEDURE 13 2 4 BEFORE INSTALLATION 13 2 5 CONDUIT AND WIRE INGRESS 14 2 6 METER INSTALLATION 15 2 7 CT INSTALLATION 15 2 8 WIRING DIAGRAM 17 2 9 MEASURING MULTIPLE LOADS WITH ONE ME...

Page 7: ...0A Optional solid core CTs available in 50 200A Parallel up to three sets of CTs for cumulative reading 1 3 Certifications UL CUL Listed 1 4 Specifications Item Description Frequency 50 60 Hz Working...

Page 8: ...tions 3 1 phase 2 wire 120V 1 or 2 phase 3 wire 120 208 240V 3 CT Rating 200 50 200A depends on CT current range 400 400A 600 600A Water meter option Water meter pulse input is an optional feature whi...

Page 9: ...is a sophisticated energy meter with multiple capabilities and functions Before installation be sure to read and understand this section and the appropriate wiring diagrams Installation of this devic...

Page 10: ...B C Phases A B C phase voltage inputs indicator P Watthour test constant indicator Kt 1Wh 1000 imp kWh Load Load status indicator DI Water meter pulse input indicator Terminal Cover To cover the termi...

Page 11: ...tage input 22 VN Phase N voltage input CT input terminals 13 CT A Phase A CT input 14 CT A Phase A CT input 15 CT B Phase B CT input 16 CT B Phase B CT input 17 CT C Phase C CT input 18 CT C Phase C C...

Page 12: ...the wires are screwed tightly onto the terminals and making good contact 3 Recommended wire size Terminal type Wire range Voltage input 10 18 AWG screw torque 16 lb inch CT input 14 22 AWG screw torq...

Page 13: ...2 4 Before Installation 1 Check that the ratings and specifications of the model to be installed is suitable for its intended application 2 Verify that the dedicated CT being used is compatible with...

Page 14: ...1 2 or 3 4 conduit For voltage and CT wirings cut open the knockout for 3 4 conduit Note Please use UL certified cables and conduits 2 Special terminal cover An alternate terminal cover is also avail...

Page 15: ...e that the direction and orientation of the CTs with wiring are consistent With solid core CTs the wire must be threaded through the CT which would necessitate disconnecting the wire from the load Wit...

Page 16: ...se refer to section 2 2 on Terminals 2 Solid core CT installation Load side With solid core CTs the wire must be threaded through the CT which would necessitate disconnecting the wire from the load Me...

Page 17: ...Wiring Diagram 1 1 phase 2 wire VAN 120V Note Please install a fuse for each voltage input Except the phase N 2 1 or 2 phase 3 wire VAN VBN 120V VAB 208 240V Note Please install a fuse for each volta...

Page 18: ...CTs must be in the same direction Each of the CTs for the same phase on different loads must be connected to the correct polarity CT white wire to the CT terminal on the meter and the CT black wire t...

Page 19: ...y The power up sequence of the Polaris shows the following information on the display Display Shows Example Description Range 1 8 8 8 8 8 8 LED display test 2 A1 xxx Reserved 3 b1 xx Reserved 4 r xxx...

Page 20: ...ively c Check to make sure that power is being supplied from the power source to the voltage input d Check that the power source voltage is within the rated power supply e Check to make sure that the...

Page 21: ...wiring is connected properly b Check the voltage input terminals are not damaged The accumulation of kWh does not match total consumption a Check to make sure the voltage input is continuously 24 hou...

Page 22: ...CT input of the Polaris can only accept milli amps which matches DAE s dedicated CTs Connecting a regular 5A output CT directly will thus damage the Polaris meters Q Can the CT lead wire be extended A...

Page 23: ...used by having the phases reversed voltage and current phases are not properly matched or there may be some run down equipment that are in need of repair or replacement Check to make sure that the vol...

Page 24: ...tract tort or otherwise shall not exceed the purchase price paid by Customer for the products claimed 6 2 Return Policy All returned material must be in good as new and in salable condition A 20 resto...

Page 25: ...circuit Our contact information US Website www DAEcontrols com US Email info DAEcontrols com US Phone 1 248 635 3708 International Website www DAEinstrument com International Email info DAEinstrument...

Page 26: ...Polaris 1000 User s Manual Page 26...

Page 27: ...Polaris 1000 User s Manual Page 27...

Page 28: ......

Reviews: