background image

1

Important Information About 

Safety Instructions

The 

• 

Important Safety Instructions

 and warnings in 

these instructions are not meant to cover all possible 

problems and conditions that can occur. Use common 

sense and caution when installing, maintaining or oper-

ating this or any other appliance.
Always contact the Dacor Customer Service Team 

• 

about problems and conditions that you don’t under-

stand. See 

Customer Service Information

 above.

Important Safety Instructions

Safety Symbols and Labels

 DANGER

Immediate hazards that 

WILL

 result in severe personal 

injury or death.

 WARNING

Hazards or unsafe practices that 

COULD

 result in severe 

personal injury or death.

 CAUTION

Hazards or unsafe practices that 

COULD

 result in minor 

personal injury or property damage.

 DANGER

IMPORTANT

: Do not store or use combustible, 

flammable or explosive vapors and liquids (such as 

gasoline) inside or in the vicinity of this or any other 

appliance. Also keep items that could explode, such 

as aerosol cans, away from the range or cooktop. Do 

not store flammable or explosive materials in adjacent 

cabinets or areas.

 WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL 

DUCTWORK.

 WARNING

WARNING - TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING:

Use this unit only in the manner intended by the 

a. 

manufacturer. If you have questions, contact the 

manufacturer. 
Before servicing or cleaning unit, switch power off 

b. 

at service panel and lock the service disconnecting 

means to prevent power from being switched on 

accidentally. When the service disconnecting means 

cannot be locked, securely fasten a prominent warn-

ing device, such as a tag, to the service panel

.

 WARNING

WARNING - TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING:

Installation work and electrical wiring must be done 

a. 

by qualified person(s) in accordance with all appli-

cable codes and standards, including fire-rated con-

struction. 
Sufficient air is needed for proper combustion and 

b. 

exhausting of gases through the flue (chimney) of 

fuel burning equipment to prevent back drafting. 

Follow the heating equipment manufacturer’s guide-

line and safety standards such as those published 

by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration 

and Air Conditioning Engineers (ASHRAE), and the 

local code authorities.
When cutting or drilling into wall or ceiling, do not 

c. 

damage electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.

d. 

 CAUTION

For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials or vapors.

READ AND SAVE THESE INSTRUCTIONS

Summary of Contents for REMP16

Page 1: ...265 Rev G Suitable for use in a household cooking area Suitable for use with solid state controls To complete this blower a Dacor hood assembly or Dacor raised vent must be purchased separately See the hood or raised vent installation instructions to determine suitability ...

Page 2: ...completely and care fully before you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s use 2008 Dacor all rights reserved If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For rep...

Page 3: ...SONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the a manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off b at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warn ing device ...

Page 4: ... the location of the fuse or circuit breaker panel so that the cus tomer knows where and how to turn the power off warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using this blower follow basic safety precautions including the following A minimum of two people are required to safely install this appliance Never allow the filters or vent ope...

Page 5: ...t Hole C L C L C L C L 26 660mm 32 1 4 819mm 3 5 8 92mm 12 1 4 311mm Mounting Flange 33 1 2 851mm 9 1 2 241mm 13 1 8 333mm Discharge Intake Collar Power Supply Conduit Location C L C L C L C L 24 1 4 616mm 9 9 16 243mm 10 Nom 254mm 11 1 2 292mm Discharge Intake Collar 5 13 16 148mm 8 Nom 203mm 7 15 16 202mm Discharge Intake Collar All tolerances 1 16 0 1 6 mm 0 unless otherwise noted REMP3 REMP16 ...

Page 6: ...ted on each end by a 1 2 UL certi fied strain relief The power is turned on and off by the power switch on the approved ventilation device The correct voltage frequency and amperage must be supplied to the hood or raised vent and the blower from a grounded single phase circuit that is protected by a properly sized circuit breaker or time delay fuse The circuit must have the capacity to supply the ...

Page 7: ... support or can be reinforced to support the weight of the blower see weight table below The unit requires a mounting sur face around the perimeter of the base of the unit 2 in width and thick enough to accommodate the 8 2 1 2 long mounting screws that are provided with the unit All contact surfaces between the blower and any mounting surfaces must be solid and at right angles See Figure 1 for the...

Page 8: ...n page 5 and meet local codes and ordi nances Consult the hood or raised vent installation instructions for additional part requirements Installation Before installing the blower unpack the unit and check 1 for physical damage to the motor and blower assembly To do so reach in through the intake collar and spin the fan blades slowly They should spin freely and qui etly without vibration Installati...

Page 9: ...e GND blower 13 power terminal see Figure 9 Tighten the terminal screw firmly into place Check the wires from the blower wiring harness to 14 make sure that they are firmly attached to the terminal according to Figure 9 Reconnect any wires that are loose Make sure all terminal screws are tight Replace the blower s top cover and screws 15 Secure the other end of the wiring conduit to the hood 16 or...

Page 10: ...EMP16 1000 CFM 994 8 CFM Airflow CFM Cubic feet minute Static pressure inches of water 0 1 0 2 0 3 0 4 0 5 0 100 200 300 400 500 600 700 REMP3 Blower Performance Airflow CFM Cubic feet minute Static pressure inches of water 0 0 5 1 0 1 5 2 0 2 5 200 400 600 800 1000 REMP16 Blower Performance At 0 static pressure ...

Page 11: ......