PLANNING

GUIDE

www.Dacor.com      Phone: (800) 793-0093  

Specifications subject to change without notice.

Install all appliances according to accompanying installation instructions.

5.15

Distinctive Range

DR30D

Note 2

E

F

2

 Cabinet/countertop depth is at discretion of customer but 

cabinet face MUST NOT protrude further than rear of front 

panel, see product dimensions.

3

 Consult local code for exact location requirements.

1

 Vertical to combustible surface from range grate level; if 

installing an overhead vent hood, also check the hood 

specifications for minimum required clearances. 

Non-combustible 

surface along 

back wall

recommended

10” (25.4 cm) Min.

to combustible side

walls above the range

(both sides)

30” (76.2 cm)

Min.

1

37 7/8

(96.2 cm)

Max.

13” (33.0 cm)

Max.

4

18” (45.7 cm)

Min.

1, 4

Suggested 

location of 

utilities

 

3

4

 Not applicable for cabinets more than a horizontal 

distance of 10” (25.4 cm) from the edge of the range.

Cutout Dimensions

E

F

36” (91.4 cm)*

30” (76.2 cm)**

30 

1

/

16

” (916mm)

* Recommended 

** Minimum

gas and Electrical Service

The shaded area shown below denotes the location of the gas inlet 

 

and the electrical junction box/receptacle. This is the recommended 

location. For replacement purposes, the location of the existing 

utilities may be utilized provided they do not interfere with the sides 

or rear of the range. Check local building codes for permissible gas 

valve locations.
An external manual shut-off valve must be installed between the gas 

 

inlet and the range for the purpose of turning on or shutting off gas to 

the appliance.

The installation must allow for the following:

Access to the gas shut-off valve when the unit is installed. 

 

Access to the remote circuit breaker panel/fuse box when the range 

 

is in place.  
The gas supply piping, gas shut-off valve and the electrical junction 

 

box or receptacle must be located so they do not interfere with the 

range when it is installed.
The junction box and gas shut off valve must be located so that 

 

the range can be pulled out for service while the appliance remains 

connected. 

Cabinet Layout

Carefully check the location where the range is to be installed. For 

 

best performance, the range should be placed away from drafts that 

may be caused by doors, windows and heating and air conditioning 

outlets.
To reduce the risk of personal injury and to reduce accumulated 

 

smoke in the room, Dacor strongly recommends installing a range 

hood. A range hood should project horizontally a minimum of five (5) 

inches beyond the face of the cabinets.
All maximum and minimum dimensions and clearances shown in the 

 

diagram below must be maintained for safe operation.
The range may be installed flush to the rear wall. A non-combustible 

 

rear wall is not mandatory, but Dacor highly recommends installing 

a non-combustible material from the countertop level up to the vent 

hood or installation of a backguard.
Any openings in the wall behind the appliance or in the floor 

 

underneath it must be sealed. 

REqUIRED cAbINEt DImENsIoNs

Cabinet tolerances: -1/16”, (+1.6mm) -0

Document # PG05 - 006

Revised 1/26/10    Page 2/2