background image

Installation Instructions .................................................... 5

Installation Preparation .................................................... 5

Installation ........................................................................ 5

Verifying Proper Operation ............................................... 6

Technical Data ................................................................... 7

Blower Ratings ................................................................. 7

Wiring Diagram ................................................................ 7

Notes................................................................................... 8

Table of Contents

Before You Begin...

Important Safety Instructions .......................................... 1

Important Information About Safety Instructions .............. 1

Safety Symbols and Labels ............................................. 1

General Safety Precautions ............................................. 2

Product Specifications ..................................................... 3

Product Dimensions ......................................................... 3

Electrical Specifications ................................................... 4

Installation Planning ......................................................... 4

All specifications subject to change without notice. Dacor

 

assumes no liability for changes to specifications.

Important:

Installer:

• 

 In the interest of safety and to minimize problems, read these installation instructions completely and care-

fully before you begin the installation process. Leave these installation instructions with the customer.

Customer:

• 

 Keep these installation instructions for future reference and for the local electrical inspector’s use.

© 2008 Dacor, all rights reserved.

If You Need Help...

If you have questions or problems with installation, contact 

your Dacor

®

 dealer or the Dacor Customer Service Team. For 

repairs to Dacor appliances under warranty call the Dacor 

Distinctive Service line. Whenever you call, have the model 

and serial number of the blower ready. The model and serial 

number are printed on the appliance data label on the unit.

Dacor Customer Service

Phone:  (800) 793-0093 (U.S.A. and Canada) 

Monday — Friday 6:00 

a

.

m

.

 to 5:00 

p

.

m

.

 Pacific Time

Web site: www.Dacor.com

Dacor Distinctive Service (for repairs under warranty only)

Phone: (877) 337-3226 (U.S.A. and Canada) 

Monday — Friday 6:00 

a

.

m

.

 to 4:00 

p

.

m

.

 Pacific Time

Customer Service Information

Model Identification

ILHSF8 = 8-inch in-line blower
ILHSF10 = 10-inch in-line blower

Summary of Contents for ILHSF10

Page 1: ...8 ILHSF10 Part No 103719 Rev E Suitable for use in a household cooking area Suitable for use with solid state controls To complete this blower the hood assembly must be purchased separately See the ho...

Page 2: ...llation instructions with the customer Customer Keep these installation instructions for future reference and for the local electrical inspector s use 2008 Dacor all rights reserved If You Need Help I...

Page 3: ...intended by the man a ufacturer If you have questions contact the manufac turer Before servicing or cleaning unit switch power off b at service panel and lock the service disconnecting means to preven...

Page 4: ...rent draw of the in line blower and the hood or downdraft vent must not exceed the maxi mum rated input current of the hood or downdraft vent warning General Safety Precautions To reduce the risk of f...

Page 5: ...20 8 cm 8 REF 8 3 16 5 7 cm 2 1 4 20 3 cm 8 REF 33 0 cm 13 15 2 cm 6 41 9 cm 16 3 16 0 5 cm 15 1 4 38 7 cm 19 48 3 cm 16 40 6 cm 8 1 4 21 0 cm 15 3 4 40 0 cm 10 3 4 27 3 cm 2 1 4 5 7 cm 10 REF 25 4 cm...

Page 6: ...duit is installed between the hood or raised vent and the blower and shall be terminated on each end by a 1 2 UL certified strain relief The power is turned on and off by the power switch on the appro...

Page 7: ...off power at the circuit breaker panel or fuse box before connecting the blower to the power source Blower Mounting Hold the blower steady in the mounting location Make 1 sure that the AIR FLOW arrow...

Page 8: ...Tighten the terminal screw firmly into place IMPORTANT The neutral terminal on the blower has the BLACK wire from the blower motor connected to it Connect the black L1 wire from the conduit to the 8...

Page 9: ...atic pressure inches of water 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 200 400 600 800 1000 1200 ILHSF10 Blower Performance Airflow CFM Cubic feet minute Static pressure inches of water 0 0 5 1 0 1 5 2 0 2 5 3 0...