Dacor ILHSF10 Installation Instructions Manual Download Page 4

2

Important Safety Instructions

Do not install or operate this unit if it has been dam-

• 

aged, dropped, has damaged electrical wiring or is 

not working properly. If the product is damaged when 

received, immediately contact the dealer or builder.
Use this blower only for its intended purpose as out-

• 

lined in these instructions. This blower is not intended 

for commercial use.
This blower must be installed and grounded by a 

• 

qualified installer according to these installation 

instructions and the hood or downdraft vent installa-

tion instructions. All planning, installation work and 

electrical wiring must be performed in accordance 

with all governing codes and ordinances, including 

fire-rated construction. Contact your local building 

department for further information.
Install or locate this appliance only in accordance 

• 

with these installation instructions and the Dacor 

hood or downdraft vent installation instructions. 

Improper installation, adjustment, alteration, service 

or maintenance can cause serious personal injury or 

property damage.
Before installing or servicing the in-line blower, make 

• 

sure that power to the wiring is turned off at the cir-

cuit breaker or fuse box. Make sure that the service 

panel is locked or tagged to prevent power from 

being switched on accidently.
To reduce the risk of electric shock or fire, the total 

• 

combined current draw of the in-line blower and the 

hood or downdraft vent must not exceed the maxi-

mum rated input current of the hood or downdraft 

vent.

 WARNING

General Safety Precautions

To reduce the risk of fire, electric shock, serious injury or death when using this blower, follow basic safety precautions, 

including the following:

The installer must show the customer the location of 

• 

the fuse or circuit breaker panel so that the customer 

knows where and how to turn the power off.
Never allow the filters or vent openings on the hood 

• 

or downdraft vent to become blocked or clogged. Do 

not allow foreign objects, such as cigarettes or nap-

kins, to be sucked into the vent holes.
Clean the filters and all grease-laden surfaces around 

• 

the hood or downdraft vent often to prevent grease 

fires and maintain performance.
Use only duct work constructed of materials deemed 

• 

acceptable by state, municipal and local codes.
Tape all duct joints securely to prevent combustion 

• 

by-products, smoke or odors from entering the home. 

Doing so will also improve system efficiency.
Do not route electrical wiring near hot surfaces.

• 

Do not ground the appliance with the neutral (white) 

• 

house supply wire. A separate ground wire must be 

utilized.
To prevent a damaged or non-functional system, 

• 

complete electrical connections properly. Follow the 

wiring diagrams carefully in the hood or in-line blower 

installation instructions to ensure a proper installation. 

After installation or service, make sure that all blower 

wires are tightly connected to their respective termi-

nals.

 WARNING

Summary of Contents for ILHSF10

Page 1: ...8 ILHSF10 Part No 103719 Rev E Suitable for use in a household cooking area Suitable for use with solid state controls To complete this blower the hood assembly must be purchased separately See the ho...

Page 2: ...llation instructions with the customer Customer Keep these installation instructions for future reference and for the local electrical inspector s use 2008 Dacor all rights reserved If You Need Help I...

Page 3: ...intended by the man a ufacturer If you have questions contact the manufac turer Before servicing or cleaning unit switch power off b at service panel and lock the service disconnecting means to preven...

Page 4: ...rent draw of the in line blower and the hood or downdraft vent must not exceed the maxi mum rated input current of the hood or downdraft vent warning General Safety Precautions To reduce the risk of f...

Page 5: ...20 8 cm 8 REF 8 3 16 5 7 cm 2 1 4 20 3 cm 8 REF 33 0 cm 13 15 2 cm 6 41 9 cm 16 3 16 0 5 cm 15 1 4 38 7 cm 19 48 3 cm 16 40 6 cm 8 1 4 21 0 cm 15 3 4 40 0 cm 10 3 4 27 3 cm 2 1 4 5 7 cm 10 REF 25 4 cm...

Page 6: ...duit is installed between the hood or raised vent and the blower and shall be terminated on each end by a 1 2 UL certified strain relief The power is turned on and off by the power switch on the appro...

Page 7: ...off power at the circuit breaker panel or fuse box before connecting the blower to the power source Blower Mounting Hold the blower steady in the mounting location Make 1 sure that the AIR FLOW arrow...

Page 8: ...Tighten the terminal screw firmly into place IMPORTANT The neutral terminal on the blower has the BLACK wire from the blower motor connected to it Connect the black L1 wire from the conduit to the 8...

Page 9: ...atic pressure inches of water 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 200 400 600 800 1000 1200 ILHSF10 Blower Performance Airflow CFM Cubic feet minute Static pressure inches of water 0 0 5 1 0 1 5 2 0 2 5 3 0...

Page 10: ...8 Notes...

Page 11: ......

Page 12: ...Dacor Phone 800 793 0093 FAX 626 403 3130 www Dacor com...

Reviews: