background image

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

ZEST HOOD 

 

Instructions Manual 

 
 
 
 

 

www.rangemaster.co.uk 

 

Summary of Contents for ZEST HOOD

Page 1: ...ZEST HOOD Instructions Manual www rangemaster co uk ...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 6 INSTALLATION 8 USE 16 MAINTENANCE 18 EN ...

Page 3: ...flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly w...

Page 4: ...y to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambè under the range hood risk of fire This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowle...

Page 5: ...eavy usage Failure to carry out cleaning as indicated will result in a fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this...

Page 6: ...nts Ref Q ty Product Components 1 1 Hood Canopy complete with Controls Light Filters Motor 2 1 Hood support plate Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12a 4 Screws 4 2 x 44 4 Q ty Documentation 1 Instruction Manual ...

Page 7: ...EN 7 7 Dimensions ...

Page 8: ...ion Sequence of operations Installation Preparing for installation Drilling the Ceiling Shelf and Fixing the support plate Connections Fitting the hood body Functional Check Disposal of Packaging Opening the Plate and preparing for assembly Unfasten the screws joining the Plate to its Cover Take the Plate and position it the right way round as shown in the figure ...

Page 9: ... in hollow bricks with 20 mm resistance thickness Drill a hole ø 10 mm insert Plugs 11 supplied immediately Ceilings with Wood Beams As per Wood Screws used not supplied Wooden shelf with a resistant thickness of 15 mm drill a hole ø 7 mm Feeding the electric supply cable drill a hole ø 10 mm Insert two screws crossing them and leaving 4 5 mm from the ceiling for solid concrete concrete plugs not ...

Page 10: ...make adjustments by turning the piece making sure that the screws do not come out of the adjustment slot The unit must be securely fastened both due to the weight of the Hood and the stress caused by occasional sideways pressure on the Appliance when in position Once the unit has been fixed make sure that the plate is stable In all cases where the Ceiling is not sufficiently strong at the point of...

Page 11: ...to be connected to the Plate mounted on the ceiling and this must be done without the weight of the Hood bearing down on the structure The system used to fix the 4 Cables comprises 3 components Threaded pawl a already mounted on the ceiling Plate Cable locking screw b provided Safety knob c provided Pass the 4 cables connected to the Hood Canopy through the respective holes in the Plate Cover afte...

Page 12: ...Pay attention to the direction in which the Plate is fixed to the ceiling Insert the safety knobs c into the respective cables with the thread to the top Insert the cable locking screws b into the respective cables ...

Page 13: ...d to the Plate Tension the Cables by pushing them upwards so that they slide inside the cable locking screw and out through the slot in the threaded pawl This is possible because the cable locking screw involves a system that allows the Cable to slide in one direction only preventing it from sliding in the other direction Make sure that the Cables are all the same length to facilitate final levell...

Page 14: ... locking screw it is possible to make adjustments to level the mobile hood canopy Once the hood has been set level the safety knobs must be tightened Warning Make sure that all 4 of the support cables are taut Make sure that none of the 4 support cables have been damaged during installation Remember that the minimum distance between the Hood and the cooker hob must be 650mm and make sure that you ...

Page 15: ...aded onto the power cable into the slot to prevent future damage Connect the Hood to the Mains Power Supply inserting a bipolar switch with a contact aperture of at least 3 mm Remove the Grease filters see paragraph Maintenance and make sure that the Power cable has been properly inserted into the Suction fan socket FITTING THE PLATE COVER Screw the Cover back onto the Plate using the screws remov...

Page 16: ...ith all the loads turned off Motor and Lights to reset the Activated Charcoal Filter alarm LED S1 turns OFF Fixed or Flashing Signals the Metal Grease Filter saturation alarm indicating that it is necessary to wash the filters The alarm is triggered after the Hood has been in operation for 100 working hours Fixed S1 When this is activated it signals the Activated Charcoal Filter saturation alarm i...

Page 17: ...atically returns to the speed set previously Press briefly for the Delay Function Can only be activated if the Intensive or 24h function is not active Activates and deactivates total shutdown of the hood motor lights after 30 minutes To disable the Delay simply press the button again or turn the motor off The led on the motor button on the hood controls will flash once every 0 5 seconds Press and ...

Page 18: ...he hood make sure that it is completely dry When fitting the filter into the hood pay attention that they are mounted in correct position the handle facing outwards Replace the lighting unit Activated Charcoal Filter This cannot be washed or regenerated and must be changed ap proximately once every 4 months or more frequently in the case of particularly intensive use CHANGING Open the light unit R...

Page 19: ......

Page 20: ...991 0302 745_ver3 161201 D001891_01 AGA RANGEMASTER GROUP PLC ...