background image

16

Installation Instructions

Verifying Proper Operation

 WARNING

Before operating the range, read the accompanying use 

and care manual completely.

1.  Before beginning the test procedure, make 

sure all range control valves are in the 

“OFF”

 

position, and all burner rings, burner caps and 

grates are properly positioned on the spill tray. 

2.  Turn on the gas supply at the shut-off valve.
3.  Connect the power cord to the electrical outlet. When 

the range is first connected, the oven indicator light 

flashes on and off for about 10 seconds while the 

range’s circuitry starts up. Wait for the light to stop 

flashing before going to step 4.

4.  Test the left front burner on the cooktop 

by pushing in and turning the control knob 

counterclockwise to the 

HIGH

 position. 

The igniter for the left front burner will 

spark continuously. It may take up to 4 

seconds for the burner to ignite, at which time the 

ignitor will stop sparking. If ignition does not occur 

within 4 seconds, turn off the knob, wait for at least 5 

minutes to allow any gas to dissipate, then repeat this 

ignition test. When the burner ignites, rotate the knob 

counterclockwise from 

HIGH 

to 

LOW

 to adjust the 

flame height progressively. When installed properly, 

the flame will be steady. It will also have a sharp, blue 

inner cone that will vary in length proportional to the 

burner size. LP gas units may have small yellow tips at 

the end of the flames, which is normal. 

5.  Repeat ignition test for the remaining cooktop burners. 

Make sure the knobs light when in the 

HIGH

 position.

6.  After testing all the cooktop burners, turn them all off.
7.  Open the oven door. Test the oven light by turning on 

the light switch on the right side of the control panel.

8.  Turn on the convection fan switch. You should hear the 

convection fan, located behind the screen at the back 

of the oven, come on.

9.  With the oven door open, turn the oven control knob 

to the 400 degree position. Both the knob itself and 

the oven ON indicator light next to the knob should 

illuminate. Within 60 seconds you should hear the bake 

burner ignite below the oven floor. It should begin to 

give off heat. 

10. Turn the oven control knob to the 

BROIL

 position. The 

bake burner should turn off. Both the oven control knob 

and the oven 

ON

 indicator light should be illuminated. 

Within 60 seconds the broil burner on the ceiling of the 

oven should ignite and begin to give off heat.

11.  Turn the oven knob to the 

OFF

 position.

If the range does not operate properly, follow these 

troubleshooting steps:

1.  Verify that the circuit breaker for the range electrical 

outlet is on and not tripped. Make sure the power cord 

is connected.

2.  Make sure the gas supply valve is in the on position 

and that the main gas valve to the building is open.

3.  Check to see if the oven burner light flashes on and 

off once a second. If it does, repair by an authorized 

service technician is required.

4.  Repeat the above tests.
5.  If the appliance still does not work, contact Dacor 

Distinctive Service at (800) 793-0093 ex. 2822. Do not 

attempt to repair the appliance yourself. Dacor is not 

responsible for the cost of correcting problems caused 

by a faulty installation.

OFF

HIGH

Normal Flame

Summary of Contents for DR30GIS

Page 1: ...ive 30 Inch Gas Range Part No 105908 Rev B THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1a 2011 STANDARD FOR HOUSEHOLD GAS COOKING APPLIANCES For use with models DR...

Page 2: ...change without notice Dacor assumes no liability for changes to specifications 2012 Dacor all rights reserved Product data label view through right side of grate with flashlight Model Identification...

Page 3: ...om a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service...

Page 4: ...a home appliance as outlined in the literature accompanying it This range is not intended for commercial use DO NOT TOUCH THE SURFACES OF THE OVEN OR COOKTOP DURING OR IMMEDIATELY AFTER USE Do not cl...

Page 5: ...EVENT OF A RANGE TOP GREASE FIRE a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVAC...

Page 6: ...rt Number Description Compatibility AER30GLBG Low profile 1 3 4 inch Standard on models DR30GIS DR30GIFS Optional on models DR30GS DR30GFS AERB30G03 3 Inch Optional on models DR30GS DR30GFS NOT compat...

Page 7: ...the product data label see inside cover for location The Electrical Supply Requirements provided below are for reference Electrical Circuit Required Total Connected Load 120 Vac 60 Hz 15 Amp 0 5 kW 4...

Page 8: ...be sealed Cabinet Layout Note 2 B A Back wall immediately behind range6 Top of finished counter 13 33 0 cm max 4 14 35 6 cm min 4 C Suggested location of utilities3 Note 5 Note 1 A B C 30 minimum 76...

Page 9: ...ce Notch countertop to width of cabinets 3 4 min 1 9 cm countertop overhang 10 min 25 4 cm to any combustibles above counter both sides 21 1 8 53 7 cm to 24 1 8 61 3 cm 20 7 8 53 0 cm 25 3 4 65 4 cm m...

Page 10: ...et opening below countertop below countertop Cabinet face Notch countertop overhang to width of cabinets 3 8 9 5 mm min countertop overhang 3 7 6 cm 10 min 25 4 cm to any combustibles above counter bo...

Page 11: ...anual Stainless steel cleaner 1 dual burner ring 1 outer dual burner cap 1 inner dual burner cap 3 standard burner caps 2 large 1 small 3 standard burner rings 2 large 1 small 2 oven racks Installatio...

Page 12: ...rs when attaching to a wood sub floor 1 Determine the location of the range center line and front panel when the range is in its final position based on the Product Dimensions on page 4 and the actual...

Page 13: ...will support wall installation of the anti tip bracket If you do not contact the base plate or you contact metal stud mounting materials the wall mounting method may not be used and the floor mounting...

Page 14: ...ions Door Removal Remove the door to make the range easier to move during the installation process WARNING Do not attempt to disengage the hinge catches with the door removed from the oven The hinge s...

Page 15: ...ttings Do not use Teflon tape or plumber s putty on flexible gas line connections Test the gas lines for leaks as instructed before use If a leak is detected open all doors and windows and allow the g...

Page 16: ...sure that the notch on the bottom of each hinge rests on top of the lower lip of each hinge receptacle before attempting to open the oven door Rotate the hinge locks toward the front of the range imm...

Page 17: ...stall dual burner ring on dual burner base Line up indentations on bottom of burner ring with pins on top of burner base STEP 1 Install standard burner rings on standard burner bases Put holes on edge...

Page 18: ...ure the knobs light when in the HIGH position 6 After testing all the cooktop burners turn them all off 7 Open the oven door Test the oven light by turning on the light switch on the right side of the...

Page 19: ...grounded three prong electrical outlet that has been installed by a licensed electrician according to these instructions and in accordance with all applicable electrical codes See pages 5 and 16 Is th...

Page 20: ...18 Notes...

Page 21: ...19 Notes...

Page 22: ...20 Notes...

Page 23: ......

Page 24: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: