background image

3

Electrical Requirements

 WARNING

To prevent an electric shock hazard, the power supply 

must meet the specifications stated below. It is the own-

er’s responsibility to make sure that the electrical service 

meets electrical requirements and that the electrical outlet 

has been properly installed by a licensed electrician.

•  The cooktop is supplied with a factory installed, 

40-inch, three-prong, grounding electrical cord. It is 

connected to the chassis at the bottom right rear corner 

(see 

Chassis Bottom Diagrams

 below). It must be 

connected to a dedicated, grounded three-prong elec-

trical outlet installed by a licensed electrician. 

•  The electrical installation, including minimum supply 

wire size and grounding, must be done in accordance 

with National Electric Code ANSI/NFPA 70* and local 

codes and ordinances. A copy of this standard may be 

obtained from:

 

National Fire Protection Association 

 

1 Batterymarch Park  

 

Quincy, MA 02269-9101

•  The correct voltage, frequency, and amperage must be 

supplied to the electrical outlet according to the product 

data label located on the bottom of the chassis. See 

the 

Gas and Electrical Requirements

 table on this 

page for reference.

•  Be certain to locate the electrical outlet so that the 

power cord may be easily disconnected if the unit 

needs service.

Gas Supply Requirements

•  Be certain that the cooktop being installed is correct 

for the gas service being provided (Natural Gas or LP 

gas). Also, if using the cooktop at an altitude above 

4000 ft. (1219 m) make sure it is equipped for high alti-

tude (“H”) operation.

•  Units equipped for high altitude operation have an “H” 

at the end of the model number listed on the 

product 

data label.

•  Units equipped for LP operation have “LP” in the 

model number listed on the product data label. See the 

Product Data Label

  section for label location.

•  Check your local building codes for the proper method 

of installation. In the absence of local codes, this 

appliance should be installed in accordance with the 

National Fuel Gas Code ANSI Z223.1/NFPA 54.

•  An external manual shut-off valve must be installed 

between the gas supply line and the cooktop for the 

purpose of turning on or shutting off gas to the appli-

ance.

•  The cooktop is shipped from the factory with a regula-

tor in the carton. Use only the regulator provided. The 

regulator must be installed between the 

gas inlet

 on the 

cooktop and the 

gas shut-off valve.

•  The regulator inlet accommodates a 3/4” gas line. The 

cooktop inlet itself is equipped with a 3/4” male NPT fit-

ting.

See the 

DYCT304G and DYCT365G 

images on the left.

DYCT304G/NG 

DYCT365G/NG

DYCT304G/LP 

DYCT365G/LP

Gas Type

Natural Gas

LP Gas

Manifold 

Pressure

5-inch Water  

column

10-inch Water 

column

Min. Gas 

Supply 

Pressure **

6-inch Water  

column

11-inch Water 

column

Max. Gas 

Supply 

Pressure

1/2 psi

1/2 psi

Total Connected 

Load

0.25 Amp.

(0.03 kW)

0.25 Amp.

(0.03 kW)

Circuit  

Requirement

120 Vac,

60 Hz, 15 Amp.

120 Vac,

60 Hz, 15 Amp.

Gas and Electrical Requirements

*

The electrical and gas data on this page is for reference 

only. If the above data does not agree with the product data 

label, 

use the data on the product data label.

** The gas supply pressure for testing the regulator setting 

shall be at least 1-inch water column (249 Pa) above the 

specified manifold pressure.

Important Safety Instructions

DYCT304G

DYCT365G

Chassis Bottom Diagrams

Summary of Contents for Discovery DYCT304GWNG

Page 1: ...Installation Instructions Discovery Gas Cooktop Models DYCT304G DYCT365G Part No 108861 Rev A...

Page 2: ...r Keep these Installation Instructions for future reference and for the local electrical inspector s use Note Dacor is not responsible for service required to correct a faulty installation 2015 Dacor...

Page 3: ...ppliance Do not touch any electrical switch or use any electri cal devices including the telephone in your building From a neighbor s phone immediately call the gas supplier Follow the gas supplier s...

Page 4: ...of the appliance WARNING General Safety Precautions To reduce the risk of fire electric shock or serious injury or death when using your appliance follow basic safety precautions including the followi...

Page 5: ...for high altitude operation have an H at the end of the model number listed on the product data label Units equipped for LP operation have LP in the model number listed on the product data label See t...

Page 6: ...DYCT304G All tolerances 1 16 1 6 mm unless otherwise noted 13 16 2 1 cm 3 3 4 9 5 cm Gas inlet Power cord Chassis Front of cooktop Top panel overhang 2 1 8 5 4 cm 5 8 1 6 cm 30 76 2 cm 21 53 3 cm 27...

Page 7: ...cord in Chassis Front of cooktop Top panel overhang 2 1 4 5 7 cm 36 76 2 cm 21 53 3 cm 4 10 2 cm Chassis height 19 1 2 49 5 cm 33 5 8 85 4 cm Including raised embosses on sides of chassis DYCT365G Po...

Page 8: ...stalled The 40 inch 101 6 cm power cord must be able to reach an electrical outlet and that electrical outlet must be easily accessible after the cooktop is installed Access to the underside of the co...

Page 9: ...Series Countertop Cutout Dimensions All tolerances 1 16 0 1 6 mm unless otherwise noted Installation Type C Minimum D E F DYCT304G with no downdraft 2 7 8 7 3 cm 19 3 4 50 2 cm 27 5 8 70 1 cm 7 1 2 1...

Page 10: ...apply excessive pressure when tightening gas connections and fittings Do not use Teflon tape or plumber s putty on flexible gas line connections Before use test the gas lines for leaks as instructed...

Page 11: ...until it drops completely into place The burners will not function properly unless all of the burner pieces are correctly seated 3 Gently set the grates on top of the spill tray Make sure that the rub...

Page 12: ...e flame height SimmerSear burners turn the control knob to the simmer setting and make sure the low level flame can be adjusted When the unit is installed correctly the flame will burn steadily It wil...

Page 13: ...ce for the cooktop located and installed according to these instructions and in accordance with all applicable codes See page 3 Has the gas supply inlet pressure been measured to ensure that it does n...

Page 14: ...PN 108900 PN 108900 Grate small PN 108901 Grate support feet 4 PN 103712 PN 103712 Stainless steel cleaner PN A302 PN A302 Model DYCT365G See the Burner Parts and Cooktop Layout on right Burner Part D...

Page 15: ...r Location LR RR CR LF RF CF DYCT365G Trim ring Spill tray Grate SimmerSear control knobs LR CR RR LF CF Burner control knob Trim ring Grate Spill tray LR RR LF RF Trim ring SimmerSear control knob Bu...

Page 16: ...s AFTER SERVICING VERIFY PROPER OPERATION 120V 60Hz POWER SUPPLY CAUSE IMPROPER AND DANGEROUS OPERATION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WIRING...

Page 17: ...K INDICATOR LED RR BK INDICATOR LED CR BK INDICATOR LED LR ISOLATOR BOARD P N 106104 L1 IGNITOR LR BURNER W N RE IGNITOR RED NO SWITCH S1 BK BK BK W RE IGNITOR IGNITOR CR BURNER N S2 BK NO SWITCH L1 R...

Page 18: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: