SYMPTOM

 

CHECK THE FOLLOWING

 

REMEDY

 

Dishwasher will not  
pump out.

1. Drain restricted.

 

2. Defective drain pump. 
3. Air lock in drain hose.

 

4. Blocked impeller. 
5. Open windings. 
6. Wiring or terminal defective.

 

7. Electronic control board

  

   

 defective.

 

1. Clear restrictions. 
2. Replace pump 
3. Check dishwasher installation.

 

4. Check for blockage and clear.

 

5. Replace windings. 
6. Repair or replace. 
7. Replace control board.

 

Dishwasher will not fill

 

with water.

 

1. Water supply turned off. 
2. Defective water inlet valve. 
3. Check fill valve screen for

  

    

obstructions. 

4. Defective pressure switch. 
5. Electronic control board  

   

defective

.

6. Wiring or terminal defective.

 

1. Turn water supply off. 
2. Replace water inlet fill valve. 
3. Disassemble and clean screen.

 

4. Repair or replace. 
5. Check/replace control board. 

6. Repair or replace.

 

Dishwasher water  
siphons out.

1. Drain line connected to a floor

 

    

drain not vented.

 

1. Install air gap at counter top.

 

Detergent left in 
dispenser.

1. Detergent allowed to stand too

  

 

   long in dispenser. 

2. Dispenser wet when detergent

 

    

was added.

 

3. Detergent cover held closed or

 

    

blocked by large dishes.

 

4. Improper incoming water

  

    

temperature to properly

  

   

dissolve detergent. 

5. See

 

“Detergent Cover Will Not 

    

Open”

.

1. Instruct customer/user.

 

2. Instruct customer/user. 

3. Instruct customer/user on

  

    

proper loading of dishes.

 

4. Incoming water temperature of

  

    

120°F is required to properly  

    

dissolve dishwashing detergent. 

Summary of Contents for Built-In Dishwasher

Page 1: ...Service Manual Built In Dishwasher...

Page 2: ...itch 3 6 Wash Motor 3 6 Checking the Wash Motor 3 6 Checking the Tachometer 3 6 Heater 3 7 Temperature Sensor and Soil Sensor 3 7 Checking the Thermistor 3 7 Checking the Soil Sensor 3 8 Drain Pump 3...

Page 3: ...tors It is EXTREMELY important that the service technician reestablish all safety grounds prior to completion of service Failure to do so will create a hazard 6 Prior to returning the product to servi...

Page 4: ...nd the amount of water in the sump are monitored by the electronic control The pressure switch assembly mounted to the right side front frame has two pressure switches a low water level and a high wat...

Page 5: ...to separate the lower and center spray arm wash water The water flowing to the center spray arm first passes through an inline water heater before entering the delivery tube The water flowing to the l...

Page 6: ...drain phase before filling for the rinse phase of the cycle Temperature Controls Options allow the consumer the choice to control the temperature at which the main wash operates The main wash water ca...

Page 7: ...t of the cycle The Sanitize outer ring will light following the wash only if 155 F is achieved Figure 5 Condensate Drying This dishwasher is designed and equipped with a condensate drying system Steam...

Page 8: ...ore longer wash cycles As the water is assessed for temperature changes it is also adjusted to maintain proper temperature throughout the cycle The control also checks the soil concentration in the wa...

Page 9: ...tor in the sump as well as the control Start a Normal wash cycle and allow the dishwasher to fill and wash for two minutes at which time press the Start Cancel pad twice 2 This will stop the dishwashe...

Page 10: ...ted to a carrier panel that is attached to the outer door panel It is covered with a mylar blanket Control Board Plugs Throughout this section references are made to the plug and pin location on the e...

Page 11: ...tch with common bracket This assembly is mounted to the right side frame behind the junction box Low Water Level Switch The low water level switch is used to maintain the water level in the sump for t...

Page 12: ...vel Switch The high water level switch is a back up or safety for the low water level switch The high water level switch is placed in series with the drain pump If the low water level switch fails to...

Page 13: ...speed at a rate of 100 RPM second until full speed is reached The motor speed also varies during Pulse Wash where the motor speed is changed from 1600 RPM to 2800 RPM to aid in cleaning the filter wh...

Page 14: ...sor housing This emitter turns DC power into a small beam of light to be transmitted to a detector in the other post As this light passes from one post to another the amount of soil in the water parti...

Page 15: ...The drain pump is mounted directly to the rear of the sump The pump cover can be removed for cleaning The discharge end of the pump has a check valve to prevent water and odors from entering the dish...

Page 16: ...sensor inside the rinse aid reservoir triggers the control to display LO when the level of rinse agent is low The LO display on the control will not affect the operation of the dishwasher Checking the...

Page 17: ...in the removal of moisture from the air The cooler drier air and condensed water are returned to the tub through the condensate vent The drying process continues until moisture is removed from the air...

Page 18: ...moved from the door assembly Disconnect dishwasher from power supply The outer door panel is mounted to the inner door panel by Phillips head screws Figure 22 Removing the outer door panel will expose...

Page 19: ...e extreme caution Door Latch Door Switch Remove outer door panel See previous section for detailed instructions Remove two screws mounting the latch switch assembly to inner door panel and then remove...

Page 20: ...e to remove See Figure 28 To reinstall upper spray arm line up locking posts in center mount with locking tabs on upper spray arm support Turn clockwise until it locks securely Lower Spray Arm Remove...

Page 21: ...center spray arm over retaining clips and press into place After replacing rack in tub reinstall rail end caps Main Delivery Tube To gain access to main delivery tube cabinet will need to be removed S...

Page 22: ...or Seal While door is open remove seal from seal mount on both sides and across top of tub To reinstall begin inserting seal at either the left or right side Place seal into channel with wide side tow...

Page 23: ...line Slide dishwasher from under countertop to gain access to cabinet Remove four screws mounting top trim to tub Also remove screws on each side that secure lower trims to cabinet Remove screws from...

Page 24: ...asher cabinet See CABINET REMOVAL for detailed instructions Remove door spring See previous section for detailed instructions Remove two screws that attach inner door panel to hinge Remove hinge retai...

Page 25: ...hat mount door seal retainer to tub Make sure the retainer gasket is in place and not torn before reinstalling the retainer Reverse order to complete assembly Pressure Switch Assembly Remove dishwashe...

Page 26: ...priate slot in sump and lock in place Complete installation by reversing procedure Inline Heater Disconnect dishwasher from power and water supplies Remove drain line Remove dishwasher from counter to...

Page 27: ...dishwasher from power and water supplies Remove drain line Remove dishwasher from countertop Lay dishwasher on its back on a protective pad Slide hose clamps on the Y hose toward heater Leave intake h...

Page 28: ...rain line Remove dishwasher from countertop Lay dishwasher on its back on a protective pad Capacitor is mounted to back frame of the unit using a mounting nut Remove cap and wires Reinstall using reve...

Page 29: ...untertop Lay dishwasher on its back on a protective pad Remove wires to sensor Remove hoses from sump pressure switches wash motor intake lower spray arm The drain pump may be removed with the sump fo...

Page 30: ...e CABINET REMOVAL for detailed instructions With cabinet removed set unit upright Remove fill hose from side vent by removing hose clamp Unscrew counterclockwise vent grate from left side wall inside...

Page 31: ...bad bearings or locked rotor 2 Motor locked due to prolonged non use 1 Replace motor 2 Rotate motor fan or impeller Motor trips out on internal thermal overload protection 1 Improper voltage 2 Seal f...

Page 32: ...ectronic control board defective 6 Wiring or terminal defective 1 Turn water supply off 2 Replace water inlet fill valve 3 Disassemble and clean screen 4 Repair or replace 5 Check replace control boar...

Page 33: ...Page 6 1 Section 6 Parts Breakdown Door And Control Panel...

Page 34: ...sh Motor Tachometer P3 10 P3 11 246 Drain Pump P3 6 P3 8 26 Inlet Valve P3 5 P3 8 1126 Dispenser P3 2 P3 8 1665 Thermistor P2 7 P2 6 10000 Dry Fan P3 3 P3 8 2088 Display Codes Readout LO Low Liquid in...

Reviews: