DACELL CO., LTD
http://www.dacell.com
TEL:+82-43-2602242, FAX : +82-43-2602245
3
2. Connection and wiring
1) AC input
: 1 and 2 ports, 110/ 220V (50Hz/60Hz).
Separate power cable from sensor cable.
Refer to 5-1).
2) HOLD
: 3 and 4 ports.
short state : current display value holding
open state : current value display(normal operation mode)
3) ANALOG OUTPUT
: 4
→
-
(GND), 5
→
+
Analog output is as following voltage or current
DIP switch 5 on : voltage output.
DIP switch 5 off : current output.
ON
Voltage Output ( 0-5V, 1-5V ,0-10V, 2-10V)
OFF
Current Output ( 0-10
㎃
, 0-20
㎃
, 4-20
㎃
)
Adjust zero point and maximum point of analog output using
zero and span VR
signal 0 : zero VR
→
0V, signal max : span VR
→
10V
zero range : -3V~
+
3V, span : 10.5V
0
~
10V : Switch 5 off
→
current output mode (0 ~ 20
㎃
)
4) SENSOR connection port
: 6,7,8,9 ports
Set the hardware and software as following conditions.