#Option-02 (RS232C)
Make wire separately from power system wiring and noise wiring.
Make sure the use of sealed cable as a sensor cable.
Indicator
Host PC
TX(Transmitting Data)
RXD(Receiving Data), Number 2 Pin
RX(Receiving Data)
TXD(Transmitting Data), Number 3 Pin
GN(Ground)
GND(Ground), 5 Pin
1. TYPE
: EIA-232C
2. Method
: half duplex, asynchronous system
3. Baud-rate
: Selection in 2400, 4800, 9600, 19200bps
4. Parity
: No Parity
5. Data bit
: 8 bit, No Parity
6. Stop bit
: 1bit
7. Stream mode (Ex. Data +1234.5 transmission)
Data format (code : ASCII)]
CODE BYTE1 BYTE2 BYTE3
BYTE4
BYTE5
BYTE6 BYTE7 BYTE8
ASCII
S
T
,
N
T
,
+
0
HEX
53H
54H
2CH
4EH
54H
2CH
2BH
30H
CODE BYTE9 BYTE10 BYTE11 BYTE12 BYTE13 BYTE14 BYTE15 BYTE16
ASCII
1
2
3
4
.
5
CR
LF
HEX
31H
32H
33H
34H
2EH
35H
0DH
0AH
1) BYTE
. DATA
S
1, BYTE2
TABLE
: S T . DATA Un
STABLE
. DATA
L
2) BYTE
: U S
OVERFLOW
: O L
. DATA UNDERFLOW
: U
3 ~ BYTE6
:
f ed
3) BYTE
4) BYTE
CARR
5) BYTE
LINE
ix
character
(, N T ,)
7 ~ BYTE14
: DATA 8 BYTE(+/-)
15
:
IAGE RETURN
16
:
FEED
17
8. Command mode : Please set to RS485 mode(OP-03:RS485 )