Operating manual for welding unit
Type: BS304 / BD306 / BS308 / BS310
BSS
BS3xx
Page 14
22.01.99
Main menu
If you want to determine the charging voltage of the capacitors by entering the stud diameter, proceed
as follows:
Action
Switch
Display
Switch on the appliance.
The display shows the last se-
lected value,
e.g. 100V.
Press the ”MODE” key at least
2sec.
The display shows the last dia-
meter
MODE
cursor blinks
Set the new value with the “UP
ARROW” or “DOWN ARROW”
key.
Example: change from 4mm to
8mm.
up
down
cursor blinks
Have you set the value?
Now confirm with the “ENTER”
key.
When a BEEP is sounded, the
appliance has accepted th new
value
ENTER
beep
The processor sets the correct
charging voltage for the selec-
ted diameter.
During setting, the symbols ap-
pearing in the display indicate
whether the charging voltage is
being increased or reduced.
or
When the setting has been
made, the value of the char-
ging voltage appears in the
display. The appliance is now
ready for operation.