5.  INSTALLATION 

For  what  concerns  pump  handling  at  the  installation  site,  please  refer  to 
section.4.2. 
Clean the well from sand or grit by applying the normal cleaning procedures. 
Place the pumping unit at the top of the well, fasten it to the hoist hook and fill 
the motor as follows: 
a)  Place the motor in vertical position. 
b)  Remove  filling  plug  (A)  and  replace  it  with  the  nipple  equipped  with  pipe 

and funnel delivered with the motor. 

c)  Remove vent plug (B) to bleed the air possibly trapped in the motor. 
d)  Holding  the  funnel  higher  than  the  vent  valve,  pour  clear  water  in  the 

motor until the mixture already in starts dropping from the vent valve. 

e)  Stop  pouring  water  in  the  motor,  screw  valve  (B)  plug  back  in  place, 

remove the nipple and screw valve (A) plug back in place. 

The  group  should  never  run  without  being  filled,  since  pump  bearings  are 
lubricated by the pumped fluid. 
Dry running should be absolutely avoided even for a very short period, since it 
might heavily damage the pump. 
Also, the pump should not rest on the well bottom as the motor would run in a 
high sand-concentration environment with a dangerous reduction of its cooling 
capacity and probable windings burn-out. 
Check  cable  connection  to  the  control  panel  terminals.  Check  also  the 
calibration of thermal protection relays, which should be set according to rated 
break power. 
Disconnect the group from main electric supply before lowering it in the well. 
Fasten  accurately  the  cable  far  end  as  the  cable  might  fall  in  the  well.  Lower 
then  the  electric  pump  into  the  well  with  the  help  of  two  supporting  brackets 
placed alternately on the pump column pipe. 
Proceed in the following way: 
a)  Connect the first column section to the pump delivery nozzle after having 

placed  a  splitted  supporting  bracket  at  the  opposite  end  of  the  pipe.  In 
case  of  threaded  column  pipes,  place  by  the  upper  end  the  suited 
threaded sleeve to avoid possible sliding between pipe and bracket. 

b)  Move the assembly with a hoist and lower it till the bracket will rest on the 

well opening. 

c)  Fasten every 2 or 3 meters the electric supply cables to the pump column 

by  means  of  suited  bands. We  recomend  a  firm  fastening,  since  slacken 
cables  will  tend  to  slide  down  along  the  pipe  due  to  their  own  weight, 
creating loose, bending sections which could violently rub against the well 
internal walls at pump startup and stopping. 

d)  Connect the second column pipe, that too coupled to a supporting bracket 

at its top. 

e)  Keep  the  assembly  lifted  and  remove  the  first  supporting  bracket,  then 

lower the unit as described at point (b). 

f) 

Repeat  this  operation  till  reaching  the  desired  depth.  The  unit  should  be 
submersed for at least f or 2 meters below the water dynamic level, such 
however  to  fulfil  its  NPSH  requirements.    The  water  level,  for  seasonal 
drop or for an excessive pump delivery compared to well feeding, should 
never  be  lower  than  the  pump  suction  chamber,  as  that  could  cause 
driving  bushes  seizing  and  motor  overheating.  Check  the  length  of  the 
column  pipe  while  lowering  the  unit,  to  make  sure  the  unit  is  installed  at 
the  right  depth.  Definitive  fastening  is  performed  by  welding    and  bolting 
the  last  pipe flange  to  the  well  opening.  In  case of threaded  pipes,  these 
have  to  be  completely  tightened  and  possibly  locked  since  the  group 
reaction torque at startup could make them loose. 

 
 
 
 
 

 

O

N

L

Y

 F

O

R

 T

R

 6

 -

 8

 -

 1

0

 -

 1

2

  

M

O

T

O

R

S

 

Summary of Contents for SS6

Page 1: ...NDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UNDERHÅLLSANVISNING Ο ΗΓΙΕΣ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΚΑΙ ΤΗ ΣΥΝΤΗΡΗΣΗ KULLANIM VE BAKIM TALİMATLARI ИНСТРУКЦИИ ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ INSTRUCŢUNI PENTRU INSTALARE ŞI ÎNTREŢINERE INSTRUÇÕES PARA A INSTALAÇÃO E A MANUTENÇÃO INSTRUKCJE OBSŁUGI I KONSERWACJI INSTALLÁCIÓS ÉS KARBANTARTÁSI UTASÍTÁS ا دات إر وا SS6...

Page 2: ...AIS page 9 ENGLISH page 17 DEUTSCH seite 24 NEDERLANDS bladz 32 ESPAÑOL pág 40 SVENSKA sid 48 ΕΛΛΗΝΙΚΑ σελ 56 TÜRKÇE sayfa 64 РУССКИЙ cтр 72 LIMBA ROMÂNĂ pag 80 PORTUGUÊS pág 88 POLSKI str 96 MAGYAR oldal 104 112 ªRte IZk ...

Page 3: ...hat they do not play with the appliance Ensure that the product has not suffered any damage during transport or storage Check that the outer casing is unbroken and in excellent conditions 1 1Safety Use is allowed only if the electric system is in possession of safety precautions in accordance with the regulations in force in the country where the product is installed for Italy CEI 64 2 1 2 Respons...

Page 4: ...antifreeze mixture to prevent internal freezing up to 30 C Motors should not be stored or installed with lower temperatures or for periods longer than 12 months however if this is unavoidable turn the shaft by hand once a month If the motor has been stored for more than 12 months disassemble it and check rotating parts and thrust bearing Just before installation drain completely the motor from the...

Page 5: ...brackets placed alternately on the pump column pipe Proceed in the following way a Connect the first column section to the pump delivery nozzle after having placed a splitted supporting bracket at the opposite end of the pipe In case of threaded column pipes place by the upper end the suited threaded sleeve to avoid possible sliding between pipe and bracket b Move the assembly with a hoist and low...

Page 6: ...no cuts cracks scratches or other damages If two cables have to be joined in parallel pay extreme attention when connecting cables of the same color 6 2 Electric system The motor is connected by the supply cable to the control panel which contains the necessary control and protection devices Since every difficulty either mechanical or electric will damage almost automatically the motor windings it...

Page 7: ...ages when lowering the pump in the well If the results are negative lift the group again and check it thoroughly For three phases units the electric resistance value should be nearly the same for each phase Check insulation resistance to the ground i e between cable end and discharge pipe using a megahoms meter Minimum value to the ground for a new pump is 10 megahoms with cold motor However if so...

Page 8: ...onstruction features the pump and motor group easily disassembled and re assembled with normal metric size shop tools If the pump adopts a non return valve consider the additional weight of the water filled column besides the group weight and use therefore a suited hoist We suggest to employ specialized personnel for assembling and disassembling 9 2 Assembling the pump motor group Check the free r...

Page 9: ...he pump is running A Too low voltage B Overload due to sand clogging bearings tend to saize C Single phase a voltage 1 5 2 times higher than normal runs through motor windings so the starter trips stopping the unit D The starter is installed in a too warm place E The starter in not correctly calibrated F Electropump blocked in a crooked sinkhole with consequent abnormal value of the absorbed curre...

Reviews: