ENGLISH

                                    

 

 

17 

 

1.  General 
1.1  Safety 
1.2  Responsibility 
2.  Pumped fluids 
3.  Technical data 
3.1  Pump and motor group 
3.2  Construction features 
3.3  Applications 
4.  Management 
4.1  Storage 
4.2  Transport 
5.  Installation 
6.  Electrical Installation 
6.1  Power supply cable connection 
6.2  Electric system 
6.3  Electric protections 
6.4  Rotation direction 
6.5  Futher instructions for six-cable  

  motors terminals connection    

7.  Commissioning and startup 
7.1  Startup 
7.2  Operation 
7.3  Running tests 
8.  Maintenance 
9.  Repairing the pump 
9.1  Disassembling the pump-motor group 
9.2  Assembling the pump-motor group 
10.  Decommissioning and 

dismantlement 

11.  Troubleshooting 

 

17 
17 
17 
17 
17 
17 
18 
18 
18 
18 
18 
19 
20 
20 
20 
20 
20 
21 

 

21 
21 
21 
21 
22 
22 
22 
22 
22 
22 
23 

 

 
 

1.  GENERAL 

 

Read this documentation 
carefully before installation. 

 
 

Installation,  electrical  connection  and  commissioning 
must be carried out by skilled personnel in compliance 
with the general and local safety regulations in force in 
the  country  of  installation  of  the  product.  Failure  to 
comply  with  these instructions not  only  causes  risk  to 
personal  safety  and  damage  to  the  equipment,  but 
invalidates every right to assistance under guarantee. 

 

 

 

 

The  appliance  is  not  intendend  for  use  by  persons 
(including  children)  with  reduced  physical,  sensory  or 
mental  capabilities,  or  lack  of  experience  and 
knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person 
responsable  for  their  safety.  Children  should  be 
supervised  to  ensure  that  they  do  not  play  with  the 
appliance.  

Ensure that the product has not  
suffered any damage during   
transport or storage.  
Check  that  the  outer  casing  is 
unbroken and in excellent conditions. 

1.1 Safety 

Use  is  allowed  only  if  the  electric  system  is  in 
possession of safety precautions in accordance with the 
regulations  in  force  in  the  country  where  the  product  is 
installed (for Italy CEI 64/2). 

 

1.2 

 

Responsibility 

The  Manufacturer  does  not  vouch  for  correct 
operation  of  the  machine  or  for  any  damage  that  it 
may  cause  if  it  has  been  tampered  with,  modified 
and/or run outside the recommended work range or 
in  contrast  with  other  indications  given  in  this 
manual. 

 

2.  PUMPED FLUIDS  

The machine has been designed and built for pumping 
water,  free  from  explosive  substances  and  solid 
particles  or  fibres,  with  a  density  of  1000  kg/m³  and  a 
kinematic  viscosity  of  1  mm²/s,  and  chemically  non-
aggressive liquids. 
Small  sand  impurities  of  50  gr./m³  -  Ø  1  mm  are 
accepted. 

 

3.  TECHNICAL DATA 

 

3.1 Pump and motor group 

The electric pump is a centrifugal multistage pump with 
submersible  motor  and  built-in  non  return  valve, 
designed to minimize friction losses. 
The  impellers  are  dinamically  balanced  and  the  shafts 
are driven by co-axial bush bearings. The electric pump 
is  manufactured  in  two  versions,  radial  flow  and  mixed 
flow. 
The  radial  version  features  compact  axial  stages  made 
of  stage  casing,  impeller  and  diffuser,  allowing  the 
assembling of a large number of stages to reach higher 
delivery heads. 
The  mixed  flow  stages  features  instead  stage  casings 
with built-in diffusers and semi-axial impellers. This kind 
of  pump  is  employed  in  place  of  radial  versions  when 
higher  capacities  are  required  with  the  same  well 
diameter. 
 
 
 
 
 

 

 

Summary of Contents for SS6

Page 1: ...NDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UNDERHÅLLSANVISNING Ο ΗΓΙΕΣ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΚΑΙ ΤΗ ΣΥΝΤΗΡΗΣΗ KULLANIM VE BAKIM TALİMATLARI ИНСТРУКЦИИ ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ INSTRUCŢUNI PENTRU INSTALARE ŞI ÎNTREŢINERE INSTRUÇÕES PARA A INSTALAÇÃO E A MANUTENÇÃO INSTRUKCJE OBSŁUGI I KONSERWACJI INSTALLÁCIÓS ÉS KARBANTARTÁSI UTASÍTÁS ا دات إر وا SS6...

Page 2: ...AIS page 9 ENGLISH page 17 DEUTSCH seite 24 NEDERLANDS bladz 32 ESPAÑOL pág 40 SVENSKA sid 48 ΕΛΛΗΝΙΚΑ σελ 56 TÜRKÇE sayfa 64 РУССКИЙ cтр 72 LIMBA ROMÂNĂ pag 80 PORTUGUÊS pág 88 POLSKI str 96 MAGYAR oldal 104 112 ªRte IZk ...

Page 3: ...hat they do not play with the appliance Ensure that the product has not suffered any damage during transport or storage Check that the outer casing is unbroken and in excellent conditions 1 1Safety Use is allowed only if the electric system is in possession of safety precautions in accordance with the regulations in force in the country where the product is installed for Italy CEI 64 2 1 2 Respons...

Page 4: ...antifreeze mixture to prevent internal freezing up to 30 C Motors should not be stored or installed with lower temperatures or for periods longer than 12 months however if this is unavoidable turn the shaft by hand once a month If the motor has been stored for more than 12 months disassemble it and check rotating parts and thrust bearing Just before installation drain completely the motor from the...

Page 5: ...brackets placed alternately on the pump column pipe Proceed in the following way a Connect the first column section to the pump delivery nozzle after having placed a splitted supporting bracket at the opposite end of the pipe In case of threaded column pipes place by the upper end the suited threaded sleeve to avoid possible sliding between pipe and bracket b Move the assembly with a hoist and low...

Page 6: ...no cuts cracks scratches or other damages If two cables have to be joined in parallel pay extreme attention when connecting cables of the same color 6 2 Electric system The motor is connected by the supply cable to the control panel which contains the necessary control and protection devices Since every difficulty either mechanical or electric will damage almost automatically the motor windings it...

Page 7: ...ages when lowering the pump in the well If the results are negative lift the group again and check it thoroughly For three phases units the electric resistance value should be nearly the same for each phase Check insulation resistance to the ground i e between cable end and discharge pipe using a megahoms meter Minimum value to the ground for a new pump is 10 megahoms with cold motor However if so...

Page 8: ...onstruction features the pump and motor group easily disassembled and re assembled with normal metric size shop tools If the pump adopts a non return valve consider the additional weight of the water filled column besides the group weight and use therefore a suited hoist We suggest to employ specialized personnel for assembling and disassembling 9 2 Assembling the pump motor group Check the free r...

Page 9: ...he pump is running A Too low voltage B Overload due to sand clogging bearings tend to saize C Single phase a voltage 1 5 2 times higher than normal runs through motor windings so the starter trips stopping the unit D The starter is installed in a too warm place E The starter in not correctly calibrated F Electropump blocked in a crooked sinkhole with consequent abnormal value of the absorbed curre...