ENGLISH
90
3.3
Structure of menu pages
On power-up, a number of presentation pages are displayed, with the name of the product and logo, then moving on to the main menu.
The name of each menu is always displayed at the top of the screen.
The main menu always displays the following items:
Status: operating status (e.g. standby, go, Fault, input functions)
Frequency: value in [Hz]
Pressure: value in [bar] or [psi] depending on the set unit of measurement.
If an event occurs, the following may be displayed:
Fault messages
Warning messages
Messages on functions associated with inputs
Special icons
The error or status conditions visible in the main menu are listed in Table 12.
Table 14: Error status messages on main page
The other menu pages vary according to the associated functions, and are described below according to the type of specification or
setting. After entering any one of the menus, the lower section of the page always shows a summary of the main operating parameters
(operating status or possible fault status, applied frequency and pressure).
This enables a constant overview of the main machine parameters.
Error and status conditions
Identifier
Description
GO
Electric pump ON
SB
Electric pump OFF
BL
Block due to water failure
LP
Block due to low power supply voltage
HP
Block due to high internal power supply voltage
EC
Block due to incorrect setting of rated current
OC
Block due to current overload on electric pump motor
OF
Block due to current overload on final stages of output
SC
Block due to short circuit on output phases
OT
Block due to overheating of final power stages
OB
Block due to overheating of printed circuit
BP
Block due to fault on pressure sensor
NC
Pump not connected
F1
Float function status/alarm
F3
System disable function status/alarm
F4
Low pressure signal function status/alarm
P1
Operating status with auxiliary 1 pressure
P2
Operating status with auxiliary 2 pressure
P3
Operating status with auxiliary 3 pressure
P4
Operating status with auxiliary 4 pressure
Com. icon with number
Operating status in multi inverter communication with specified address
Com. icon with E
Error status in communication of multi inverter system
E0...E16
Internal error 0...16
EE
Writing and reading on EEprom of factory settings
WARN.
Low voltage
Warning due to power supply voltage failure
Summary of Contents for AD 1.0 AC
Page 13: ...ITALIANO 11 Figura 2 Fissaggio e distanza minima per la circolazione d aria...
Page 74: ...ENGLISH 72 Figure 2 Fixture and minimum clearance for air circulation...
Page 135: ...FRAN AIS 133 Figure 2 Fixation et distance minimum pour la circulation de l air...
Page 196: ...DEUTSCH 194 Abbildung 2 Befestigung und Mindestabstand f r die Luftzirkulation...
Page 257: ...ESPA OL 255 Figura 2 Fijaci n y distancia m nima para la circulaci n del aire...
Page 269: ...ESPA OL 267 Figura 13 Ejemplo de conexi n de las entradas...
Page 312: ...310 IEC 60634 1...
Page 313: ...311 1 6 1 1...
Page 317: ...315 1 2 1 1 1 1 2 5 2 1 2 1 2 2...
Page 318: ...316 2...
Page 319: ...317 2 2 3 3 15 2 2 1 1a 2a...
Page 320: ...318 4a 5b 1b 127 240 240 480 3 6 3b...
Page 324: ...322 2 2 2 GP GI 6 6 4 6 6 5 8 A B C D...
Page 332: ...330 3 14 64 X 128 4 MODE SET 12 9 MODE 1 SET 11 3 EEprom SET 6 SET MODE 3 1 11...
Page 333: ...331 3 2 1 2 3 2 1 MODE SET MODE 10 2 2 5 5 5 2 2 12...
Page 335: ...333 3 2 2 13 SET 15 15 14 16...
Page 337: ...335 17 15 15 3 4 PW 6 6 16 GO SB...
Page 338: ...336 4 4 1 Link 8 4 2 4 2 1 Link Link 16 18 Link...
Page 367: ...365 OC 10 6 OF 10 6 33 8 8 1 PMW 4 2 8 2 8 3 8 3 SET EE EEprom FLASH...
Page 379: ...NEDERLANDS 377 Afbeelding 2 Bevestiging en minimumafstand voor luchtrecirculatie...
Page 440: ...SVENSKA 438 Fig 2 Fasts ttning och min utrymme f r luftcirkulation...
Page 501: ...T RK E 499 ekil 2 Hava sirk lasyonu tesisat ve minimum a kl k...
Page 556: ...554 IEC 364 1 inverter...
Page 557: ...555 1 Inverter inverter inverter 6 inverter 1 1...
Page 561: ...559 1 2 1 1 inverter inverter 1 1 2 5 inverter 2 1 inverter 2 1 2 2 C...
Page 562: ...560 2...
Page 563: ...561 2 2 3 3 inverter 15 inverter 2 2 1 inverter inverter 1a 2a...
Page 564: ...562 4a 5b 1b V 127 240 240 480 mm 3 6 3b azione...
Page 568: ...566 2 2 2 inverter inverter GP GI 6 6 4 6 6 5 inverter 8 A B C D...
Page 576: ...574 3 14 oled 64 X 128 4 MODE SET 12 inverter 9 MODE 1 SET 11 3 EEprom SET 6 SET MODE 3 1 11...
Page 577: ...575 3 2 1 2 3 2 1 MODE SET Setpoint MODE 10 ONOMA TOY MENOY 2 Setpoint 2 5 5 5 2 2 12...
Page 581: ...579 17 15 15 3 4 Password inverter password password inverter password PW 6 6 16 GO SB FAULT...
Page 623: ...ROM N 621 Figura 2 Fixarea i distan a minim pentru circula ia aerului...
Page 684: ...POLSKI 682 Rys 2 Mocowanie oraz minimalna odleg o na potrzeby cyrkulacji powietrza...
Page 745: ...MAGYAR 743 2 bra R gz t s s minim lis t vols g a szell z leveg kering se rdek ben...
Page 800: ...798 IEC 364 1...
Page 801: ...799 1 3 1 1...
Page 805: ...803 1 2 1 1 1 1 2 5 2 1 2 1 2 C...
Page 806: ...804 2...
Page 807: ...805 2 2 3 3 15 2 2 1 1 2a...
Page 808: ...806 4a 5b 1b V 127 240 240 480 3 6 3b...
Page 812: ...810 2 2 2 GP GI 6 6 4 6 6 5 8 A B C D...
Page 817: ...815 V 36 36 12V A 3 3 3 3 2 13 9 11 8 13...
Page 819: ...817 3 14 64 X 128 4 MODE SET and 12 9 MODE 1 SET 11 3 EEprom SET 6 SET MODE 3 1 11...
Page 820: ...818 3 2 1 2 3 2 1 10 2 2 5 5 5 2 2 12...
Page 824: ...822 15 3 4 GO SB FAULT...
Page 825: ...823 4 4 1 8 4 2 4 2 1 16 18...
Page 862: ...ESKY 860 Obr zek 2 P ipevn n a minim ln vzd lenost kv li cirkulaci vzduchu...
Page 917: ...915 IEC 60634 1...
Page 918: ...916 1 6 1 1...
Page 922: ...920 1 2 1 1 1 1 2 5 2 1 2 1 2 2...
Page 923: ...921 2...
Page 924: ...922 2 2 3 3 15 2 2 1 1a 2a...
Page 925: ...923 4a 5b 1b 127 240 240 480 3 6 3b...
Page 929: ...927 2 2 2 GP GI 6 6 4 6 6 5 8 A B C D...
Page 931: ...929 10 4 20 6 4 20 PR 6 5 7 4 20 2 18 J5 GND 1 J5 GND o IN 11 J5 4 20 7 OUT 8 10 11 IN...
Page 935: ...933 13 J5 I1 11 17 16 18 16 17 I2 11 15 16 18 15 16 I3 11 14 13 18 13 14 I4 11 12 13 8 12 13 9...
Page 937: ...935 3 14 64 X 128 4 MODE SET 12 9 MODE 1 SET 10 3 EEprom SET 6 SET MODE 3 1 11...
Page 938: ...936 3 2 1 2 3 2 1 MODE SET MODE 10 2 2 5 5 5 2 2 11...
Page 940: ...938 3 2 2 13 SET 15 15 14 16...
Page 942: ...940 17 14 15 3 4 PW 6 6 16 GO SB FAULT...
Page 943: ...941 4 4 1 Link 8 4 2 4 2 1 Link Link 16 18 Link...
Page 946: ...944 4 3 1 2 1 4 3 1 3 SET MODE LA RC MS FS SO AE O1 1 O2 2 4 4 2 2 4 2 5 4 5 ET 6 6 9 FL...
Page 969: ...967 10 0 Mode Set PW 0 PW 2 7 3 6 6 16 1 PW PW PW PW 0 PW 0 0 PW PW PW PW PW 0 PW...