DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
22
No.
Name
Range
Factory Setting
o630*
Alarm if there is an error as configured in o631-o639. The
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes
0.00
o631*
Alarm for faulty safety edge. Time as in o630.
0 - 1
0
0
Disabled
1
Constant signal
o632*
Alarm for critical error message in display
0 - 1
0
0
Disabled
1
Constant signal
o633*
Alarm if stop circuit interrupted
0 - 1
0
0
Disabled
1
Constant signal
o634*
Alarm if door open
0 - 1
0
0
Disabled
1
Constant signal
o635*
Alarm if door is in mid position
0 - 1
0
0
Disabled
1
Constant signal
o636*
Alarm if door is in closed position
0 - 1
0
0
Disabled
1
Constant signal
o637*
Alarm if vehicle loop 1 is activated
0 - 1
0
0
Disabled
1
Constant signal
o638*
Alarm if vehicle loop 2 is activated
0 - 1
0
0
Disabled
1
Constant signal
o639*
Alarm if photocell interrupted
0 - 1
0
0
Disabled
1
Constant signal
o642*
Alarm for uncritical error message in display
0 - 1
0
0
Disabled
1
Constant signal
o683
Inversion of contact function for output
1 - 2
1
1
Normally open, NO
2
Normally closed, NC
* = Only when o600 is set to 4.