DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
16
No.
Name
Range
Factory Setting
o422
Function during warning time
1 - 2
1
1
Output signal disabled during warning in other output
2
Output signal as configured in o410-o413
o423
Flashing frequency
0.1-2.0 seconds
0.5
o430*
Alarm if there is an error as configured in o431-o439. The
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes
0.00
o431*
Alarm for faulty safety edge. Time as in o430.
0 - 1
0
0
Constant signal
1
Active
o432*
Alarm for critical error message in display
0 - 1
0
0
Constant signal
1
Active
o433*
Alarm if stop circuit interrupted
0 - 1
0
0
Disabled
1
Constant signal
o434*
Alarm if door open
0 - 1
0
0
Disabled
1
Constant signal
o435*
Alarm if door is in mid position
0 - 1
0
0
Disabled
1
Constant signal
o436*
Alarm if door is in closed position
0 - 1
0
0
Disabled
1
Constant signal
o437*
Alarm if vehicle loop 1 is activated
0 - 1
0
0
Disabled
1
Constant signal
o438*
Alarm if vehicle loop 2 is activated
0 - 1
0
0
Disabled
1
Constant signal
o439*
Alarm if photocell interrupted
0 - 1
0
0
Disabled
1
Constant signal
o442*
Alarm for uncritical error message in display
0 - 1
0
0
Disabled
1
Constant signal
o483
Inversion of contact function for output
1 - 2
1
1
Normally open, NO
2
Normally closed, NC
* = Only when o400 is set to 4.