DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
10
No.
Name
Range
Factory Setting
o230*
Alarm if there is an error as configured in o231-o239. The
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes
0.00
o231*
Alarm for faulty safety edge. Time as in o230.
0 - 1
0
0
Constant signal
1
Active
o232*
Alarm for uncritical error message in display
0 - 1
0
0
Constant signal
1
Active
o233*
Alarm if stop circuit interrupted
0 - 1
0
0
Disabled
1
Constant signal
o234*
Alarm if door open
0 - 1
0
0
Disabled
1
Constant signal
o235*
Alarm if door is in mid position
0 - 1
0
0
Disabled
1
Constant signal
o236*
Alarm if door is in closed position
0 - 1
0
0
Disabled
1
Constant signal
o237*
Alarm if vehicle loop 1 is activated
0 - 1
0
0
Disabled
1
Constant signal
o238*
Alarm if vehicle loop 2 is activated
0 - 1
0
0
Disabled
1
Constant signal
o239*
Alarm if photocell interrupted
0 - 1
0
0
Disabled
1
Constant signal
o242*
Alarm for uncritical error message in display
0 - 1
0
0
Disabled
1
Constant signal
o283
Inversion of contact function for output
1 - 2
1
1
Normally open, NO
2
Normally closed, NC
* = Only when o200 is set to 4.