background image

6

Tensioned Professional Electrol® Installation

Screen Adjustment

240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH:

Da-Lite offers two styles of 240 volt wall switches for  
standard operation. Please see wiring diagram in wall switch 
box included with screen.

Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at Da-Lite.

CAUTION: Contact Da-Lite at 800-622-3737 or 574-267-8101 if screen motor needs adjustment.

ATTENTION: Contactez Da-Lite au 800-622-3737 ou au 574-267-8101 au cas le moteur de l'écran a besoin d'être ajusté.

Black With 

Yellow

To junction box mounted in screen 
case, in which interal wiring terminates 
in white, black, and red leads.

In multiple control 
installations the switch is 
replaced by the low 
voltage control,  
operated  
from push  
button  
stations.

Operating switch, 
switch box, and 
plate furnished with 
screen. (SPDT with 
center off)

Up

Down

Side View Of 

Switch & Box

AC Common

Green 

(Ground)

Red 

(Up)

Green (Ground)

AC Hot

115V. AC 60HZ 
1 AMP. MAX.

This switch cannot be used with L.V.C.

NOTE:

 A single switch cannot be used to operate more than one 

screen. Contract the factory for further information.

120V Wiring Diagram

Motor

Green (Ground)

Green (Ground)

Black (Down)

Black (Do

wn)

Black 

(Down)

Red (Up)

R

ed (Up)

White (Common)

Whit

e (Common)

Off

Summary of Contents for Tensioned Professional Electrol

Page 1: ...INSTRUCTION BOOK FOR Tensioned Professional Electrol...

Page 2: ...iance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently 5 The use of an accessory attachment not r...

Page 3: ...cement 2 Make sure hangers are placed to fit into notches of ironing board Installation 11 1 2 11 1 2 Screens Over 22 Wide Figure 3 11 1 2 11 1 2 Screens 22 Wide And Under Case Length 2 Case Length 2...

Page 4: ...cut wrapping paper with knive or any sharp tool Remove by hand ATTENTION Ne coupez pas le papier d emballage ou le ruban adh sif avec un couteau ou un outil tranchant Retirez la main 5 Install electr...

Page 5: ...een to conceal it when not in use Do not seal in allow access Wall or Ceiling Mount With Hangers Wall type hangers and ceiling type hangers are standard equipment One set is supplied with each screen...

Page 6: ...s le moteur de l cran a besoin d tre ajust Black With Yellow To junction box mounted in screen case in which interal wiring terminates in white black and red leads In multiple control installations th...

Page 7: ...across red and white leads Power at junction box Thermal overload tripped Let motor cool down for 15 minutes Try again Broken wire in the down or up position Check for continuity Cut off old splice an...

Page 8: ...AXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of f...