background image

4

TENSIONED COSMOPOLITAN

®

 ELECTROL

®

 INSTALLATION

LOW-VOLTAGE WALL SWITCH

OPTIONAL IR AND RF 

REMOTE CONTROL

MOTOR

BLUE (COMMON)

BROWN (HOT)

GREEN

GROUND TO CASE

240VAC 50HZ

240V WIRING DIAGRAM 

WITH OPTIONAL BUILT-IN 

LOW VOLTAGE CONTROL

RJ9

UP

STOP

DOWN

GROUND–MUST BE 

CONNECTED TO 

BUILDING GROUND

RJ9

GREEN

FRONT

BACK

UP   DN

GND   +5V

3-POSITION 

SWITCH

RJ9

ILT RJ9 PIN-OUTS

(TAB IS FACING UP)

 

IR or UP 

BLACK

 

GND COMMON 

RED

 

+5V 

GREEN

 

DN or DATA 

WHITE

DRY CONTACTS

SPLITTER

UP

+5V

 COM

DN

FIGURE 6

IMPORTANT NOTE:

 The wall switch is REQUIRED to make any limit 

switch adjustments, EVEN if a third party control 

system is used. Therefore, it is advised to wire the 

switch or provide a 4-conductor connection that is 

accessible.

CONNECT SUPPLIED 

RJ9 CABLE TO 

SPLITTER AND 

SWITCH, OR USE 4 

CABLE CONDUCTOR 

TO CONNECT TO 

SCREW TERMINALS.

The screen surface travel is stopped automatically in the fully opened and closed positions by limit switches that are 

properly adjusted at Da-Lite. The screen should not be adjusted for more or less drop. The fabric cables are adjusted for 

proper vertical and lateral tension at Da-Lite.
Should the picture surface get out of adjustment and it be necessary to adjust picture surface drop, proceed in the 

following manner.

NOTE:

 Use a small flat screwdriver or 5/32" Allen wrench to make adjustments.

SETTING THE DOWN LIMIT POSITION

TO REDUCE SCREEN DROP:

Turn the white limit switch screw (Figure 3) clockwise to decrease the amount of screen drop. Run the screen 

down to test the stop position. If the screen drops too far, raise the screen about one foot and adjust the limit 

switch again. Repeat until the desired position is set.

TO INCREASE SCREEN DROP:

Turn the white limit switch screw counterclockwise to increase the amount of screen drop. Run the screen down to 

test the stop position. If the screen does not drop enough, raise the screen about one foot and adjust the limit 

switch again. Repeat until the desired position is set. 

CAUTION: Do not adjust for more drop than what was ordered. At least 1-1/2 wraps of fabric must remain on the roller. This 
screen comes standard with 12" black at the top.

NOTE:

 The slat bar will not retract completely into the case.  DO NOT adjust the up limit travel any higher than the factory 

preset position or damage may occur.

SCREEN ADJUSTMENT FOR SCREENS WITHOUT A BUILT-IN LOW VOLTAGE CONTROL

s

!

Summary of Contents for TENSIONED COSMOPOLITAN ELECTROL

Page 1: ...st Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com Instruction Book for Tensioned Cosmopolitan Electrol For Sizes UpTo 10 x10 The Da Lite Difference ...

Page 2: ...pletely sealed in recessed installation Allow access for service Picture surface is centered in case Case extends 5 1 2 beyond surface on either end Do not attach anything to screen slat rod or bottom fabric pocket 1 Make sure screen is level Use a carpenter s level and plumb level CAUTION Do not cut wrapping paper or tape with knife or any sharp tool Remove by hand 2 Install electrical hook up th...

Page 3: ...VIEW OF SWITCH AND BOX THIS SWITCH CANNOT BE USED WITH LVC NOTE A single switch cannot be used to operate more than one screen Contact the factory for further information DOWN BLACK BLACK UP WHITE RED DOWN AC HOT OFF COMMON WHITE BLACK WITH YELLOW UP RED ROCKER SWITCH AC COMMON 120 V 60 HZ 2 5 MAX AMP 120V WIRING DIAGRAM DOWN WHITE LIMIT SWITCH ADJUSTMENT IN MULTIPLE CONTROL INSTALLATIONS THIS SWI...

Page 4: ...h is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible FIGURE 4 120V WIRING DIAGRAM WITH OPTIONAL BUILT IN LOW VOLTAGE CONTROL GROUND MUST BE CONNECTED TO BUILDING GROUND RJ 14 PIN OUTS TAB IS FACING UP FIGURE 5 IMPORTANT Note The wall switch is REQUIRED to mak...

Page 5: ...l and lateral tension at Da Lite Should the picture surface get out of adjustment and it be necessary to adjust picture surface drop proceed in the following manner NOTE Use a small flat screwdriver or 5 32 Allen wrench to make adjustments SETTING THE DOWN LIMIT POSITION TO REDUCE SCREEN DROP Turn the white limit switch screw Figure 3 clockwise to decrease the amount of screen drop Run the screen ...

Page 6: ... the cover plate from the 3 button wall switch and remove the switch from the junction box 2 Locate the two tactile buttons on the back of the switch They are square silver with black round buttons See Figure 4 VPI or Figure 5 LVC for diagram 3 To adjust the down limit switch press and hold the down tactile button until the LED on back of switch turns solid red This will put the motor in limit set...

Page 7: ...it switch out of adjustment a Gear noise a Defective brake a Pin end slipped out of nylon bearing Solution a Verify 115 125V or 220 240V If insufficient voltage rewire incoming electric line b Replace fuse c Reset circuit breaker d Check above Tighten all loose wire connections Correct any improper connections Down Position Check for power across black and white leads Up Position Check for power a...

Page 8: ...e by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated b...