background image

TROUBLESHOOTING

SYMPTOM

 1.   screen will not operate.
    motor does 

not

 hum. 

 

 
 

 

 

 
 

 

 

 

2.

  

Incorrect stopping position in  

  

downward 

direction.

3.

  

Incorrect stopping position in  

  

upward 

direction.

4.

  

noise. 

  

NOTE: Screen will operate with a  

    low pitched hum.

5.

  

Coasting.

CAUSE

(a)   Incorrect line voltage. 

 

(b)  blown fuse.
(c)  Tripped circuit breaker.
(d)   no power to operating switch     

or junction. 

 

 

 
Power at junction box 

(e)   Thermal overload tripped. 

(f)  broken wire in the 

“down”

 or 

“up”

         

 position.

(g)   defective motor, limit switch or 

capacitor.

(h)  Capacitor burned out.

(a) 

“Down” 

limit switch out of         

 adjustment

(a) 

“Up” 

limit switch out of              

 adjustment 

(a)  gear noise. 

 
(a)   defective  brake.

SOLUTION

(a)  Verify 115-125V (or 220-240V). If 

insufficient voltage, rewire 
incoming electric line.

(b)   Replace  fuse.
(c)  Reset circuit breaker.
(d)  Check above. Tighten all loose 
 

wire connections. Correct any 

 

improper connections.

 

“Down” Position

 

 Check for power across black  
and white leads.

 

“Up” Position

 

 Check for power across red 
and white leads.

 
 

(e)  let motor cool down for 15     
 

minutes. Try again.

(f)  Check for continuity. Cut off old  
 

splice and reconnect.

(g)   Replace motor assembly. 

NOTE: Motor is a sealed assembly.

(h)   Replace motor assembly.

(a)  Contact da-lite at 800-622-3737  
 

or 574-267-8101.

(a)  Contact da-lite at 800-622-3737  
 

or 574-267-8101.

 
(a)   Replace motor assembly. 

 
(a)   Replace motor assembly.

6

Visit www.da  -lite.com/products/tutorials.php to find installation and troubleshooting tutorials.  You will also 

find a link to Live Chat for interactive support and you can contact us by email at [email protected] or by phone 

at (800) 622-3737 or (574) 267-8101 with any troubleshooting questions.

Summary of Contents for TENSIONED CONTOUR ELECTROL

Page 1: ...it Street Post Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com Instruction Book for Tension...

Page 2: ...with a current rating at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may overheat 4 To reduce the risk of electric shock do not disassemble thi...

Page 3: ...fully seated on the bracket Tighten the stop screws against the wall bracket Ceiling Mount 1 Do not remove the wall mount bracket even if you are not using it for mounting This provides structural sta...

Page 4: ...creen Test installation by running screen up and down a few times Be prepared to stop screen Standard Duty Cycle 1MIN ON 3 MIN OFF NOTE Must be installed in accordance with the requirements of the Loc...

Page 5: ...The red wire from the VPI is the signal and the black wire from the VPI is the ground 2 Connect the wires from the VPI that are labeled Low Voltage Connection to the end of the extended screen trigger...

Page 6: ...ED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible UP STOP DOWN POWE...

Page 7: ...coming electric line b Replace fuse c Reset circuit breaker d Check above Tighten all loose wire connections Correct any improper connections Down Position Check for power across black and white leads...

Page 8: ...by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS...

Reviews: