5
TENSIONEd CONTOUR
®
ELECTROL
®
INSTALLATION
LOW-VOLTAGE WALL SWITCH
OPTIONAL IR AND RF
REMOTE CONTROL
MOTOR
BLUE
(COMMON)
BROWN
(HOT)
GREEN
GROUND TO CASE
240VAC 50HZ
240V WIRING DIAGRAM
WITH OPTIONAL BUILT-IN
LOW VOLTAGE CONTROL
Rj9
UP
STOP
DOWN
GROUND–MUST BE
CONNECTED TO
BUILDING GROUND
Rj9
GREEN
FRONT
BACK
UP DN
GND +5V
3-POSITION
SWITCH
Rj9
ILT Rj9 PIN-OUTS
(TAB IS FACING UP)
IR or UP
BLACK
GND COMMON
RED
+5V
GREEN
DN or DATA
WHITE
DRY CONTACTS
SPLITTER
UP
+5V
COM
DN
IMPORTANT NOTE:
The wall switch is ReQuIRed to make any limit
switch adjustments, eVen if a third party control
system is used. Therefore, it is advised to wire the
switch or provide a 4-conductor connection that is
accessible.
120V WIRING DIAGRAM
WITH OPTIONAL BUILT-IN
LOW VOLTAGE CONTROL
GROUND–MUST BE
CONNECTED TO
BUILDING GROUND
Rj-14 PIN-OUTS
(TAB IS FACING UP)
IMPORTANT NOTE:
The wall switch is ReQuIRed to make any limit switch
adjustments, eVen if a third party control system is
used. Therefore, it is advised to wire the switch or
provide a 3-conductor connection that is accessible.
UP
STOP
DOWN
POWER INPUT 120VAC / 60HZ
GREEN (GROUND)
BLACK (HOT)
WHITE (COMMON)
POWER WIRE
DATA
CABLE
Rj-45 jACK
Rj-45
RECEPTACLE
Rj-22
OUTPUT
Rj-22
jACK
Rj-22
INPUTS
Rj-22
jACK
LED
UP LIMIT
TACTILE
BUTTON
DOWN LIMIT
TACTILE
BUTTON
FRONT OF
WALL SWITCH
BACK OF
WALL SWITCH
Rj-22 PIN-OUTS
(TAB IS FACING UP)
Rj-45 PIN-OUTS
(TAB IS FACING UP)
Standard Rj-22 can be used in place of Rj-14
Supplied Rj-14 cable
BLUE
YELLOW
GREEN
RED
BLACK
WHITE
+12V
BUS (RP DATA)
RQ DATA
+5V
GND
RQ CLOCK
BUS (RP DATA)
RQ DATA
+5V
GND
WHITE
GREEN
RED
BLACK
BLUE
YELLOW
GREEN
RED
BLACK
ORANGE
BROWN
PURPLE
+12V
BUS (RP DATA)
RQ DATA
+5V
GND
RQ CLOCK
MANUAL 1
MANUAL 2
DRY CONTACTS
UP
DOWN
COMMON
BUS
5V
BUS
BUS
COM 5V
BUS
3-conductor 20-24 gauge wire can be used in place of
the supplied RJ-14 cable to connect the wall switch.
Connect the bus terminals on the wall switch to the
corresponding bus terminals on the splitter board.