4
TENSIONEd CONTOUR
®
ELECTROL
®
INSTALLATION
uP
off
doWn
ThIs sWITCh Can noT
be used WITh lVC.
120V WIRING DIAGRAM
FOR STANDARD
WALL SWITCH
240V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROjECTOR INTERFACE
sPdT sWITCh WITh
CenTeR off
aC (Common)
aC hoT 120VaC 60hZ 1 amP
blaCk/
YelloW
blaCk
Red
W
h
IT
e
bla
C
k (
do
W
n
)
R
ed
(u
P)
JunCTIon boX
loCaTed In lefT endCaP
WhITe
blaCk
Red
gReen
moToR
noTe: a sIngle sWITCh CannoT be used To oPeRaTe moRe Than
one sCReen. ConTaCT The faCToRY foR fuRTheR
InfoRmaTIon.
gRound–musT be ConneCTed
To buIldIng gRound
gRound To Case
blue
(Common)
blaCk
blue
(Common)
bRoWn
(doWn)
blaCk (uP)
240VaC/50hZ
PoWeR souRCe
5/12 VolT sCReen TRIggeR on PRoJeCToR
gReen
/
YelloW
(gRound)
Red
bRoWn
(hoT)
gReen
/
YelloW
(gRound)
Red
blaCk
WhITe
fRonT of
Wall sWITCh
baCk of Wall
sWITCh
uP
sToP
doWn
240 VOLT WIRING DIAGRAM FOR STANDARD
WALL SWITCH:
da-lite offers two styles of 240 volt wall
switches for standard operation. Please see
wiring diagram included in wall switch box
included with screen.
CAUTION: THE PROjECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO
THE PROjECTOR. FAILURE TO DO SO MAY DAMAGE THE CONTROLLER.
1.
use 2-conductor 20-24 gauge wire to extend the low voltage connection from the
projector’s 5 or 12-volt screen trigger output to the length required to reach the VPI.
When extending the low voltage connection from the projector’s screen trigger output,
be sure to maintain the proper polarity. The red wire from the VPI is the “signal” and the
black wire from the VPI is the “ground”.
2.
Connect the wires from the VPI that are labeled “low Voltage Connection” to the end
of the extended screen trigger wires above.
120V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROjECTOR INTERFACE
5/12 VolT sCReen
TRIggeR on PRoJeCToR
CAUTION: THE PROjECTOR MUST BE TURNED OFF BEFORE CONNECTING THE
TRIGGER WIRES TO THE PROjECTOR. FAILURE TO DO SO MAY DAMAGE THE
CONTROLLER.
use 2-conductor 20-24 gauge wire to extend the low voltage connection
from the projector’s 5 or 12-volt screen trigger output to the length
required to reach the VPI. When extending the low voltage connection
from the projector’s screen trigger output polarity does not matter. The
red and black wires from the VPI are interchangeable.
gRound–musT be ConneCTed
To buIldIng gRound
UP
STOP
DOWN
POWER INPUT 120VAC / 60HZ
gReen (gRound)
blaCk (hoT)
WhITe (Common)
PoWeR
WIRe
daTa
Cable
RJ-45
JaCk
RJ-45
ReCePTaCle
RJ-22 ouTPuT
RJ-22 JaCk
RJ-22
InPuTs
RJ-22
JaCk
led
uP lImIT
TaCTIle
buTTon
doWn
lImIT
TaCTIle
buTTon
fRonT of
Wall sWITCh
baCk of
Wall sWITCh
blaCk
Red
VPI TRIggeR
module
IMPORTANT NOTE:
The wall switch is ReQuIRed to make any limit switch adjustments,
eVen if a third party control system is used. Therefore, it is advised to
wire the switch or provide a 3-conductor connection that is accessible.
3-conductor 20-24 gauge wire can be used in place of the supplied RJ-14
cable to connect the wall switch. Connect the bus terminals on the wall
switch to the corresponding bus terminals on the splitter board.
dRY ConTaCTs
uP
doWn
Common
bus
5V
bus
BUS
COM
5V
bus