background image

SENIOR ELECTROL

®

 INSTRUCTIONS

3

SIDE VIEW

END VIEW

BOTTOM VIEW

OUTLET

BOX

SUGGESTED

SLOT WIDTH

PICTURE

SURFACE

WALL OR CEILING TYPE HANGER

12

3

16

12

3

16

3

4

3

4

3

4

3

4

3

4

11

3

8

±

1

16

18

5

8

2

9

1

2

±

1

4

“B“

3

4

HINGED ACCESS PANEL IN BOTTOM (FOR ALL WIRING & ADJUSTMENTS)

8 ±

1

4

“A“± 

1

4

LENGTH A=FABRIC WIDTH “B“

PLUS 23" ALL SIZES

NOTE: INSTALL THIS BRACKET FOR

CEILING TYPE HANGER ONLY

10" OVERALL WIDTH OF BRACKET

3

4

" DIAMETER

HOLES

3

8

" NUT & BOLT

2"

2

7

8

"

2

7

8

"

2"

4"

3

3

4

"

3

16

"

7

8

"

9

1

2

"

3

3

4

"

4

3

8

FIG. 3

 

   

NOTE: Adjustments should not be necessary to screen in the rolled up or closed position. If necessary, use the following
procedures:

PICTURE SURFACE ROLLS TOO FAR INTO CASE

  1.  Lower picture surface approximately two feet with operating switch.
  2.  Place operating switch in 

“off”

 position.

  3.  Turn the 

“up”

 limit knob one-quarter turn clockwise.

  4.   Press operating switch to raise picture surface. Repeat operation if  

picture surface continues to roll too far into case.

PICTURE SURFACE DOES NOT ROLL COMPLETELY INTO CASE

  1.  Place operating switch in 

“up”

 position.

  2.  Turn the 

“up”

 limit knob one-quarter turn counterclockwise.

  3.   Test by lowering picture surface approximately two feet with operating switch, then raise picture. Repeat operation 

if desired position is not reached.

PICTURE SURFACE ROLLED UP OR CLOSED POSITION

RAISE     LOWER

RAISE     LOWER

DOWN

UP

Summary of Contents for senIor electrol

Page 1: ...NC 3100 North Detroit Street Post Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 www da lite com e mail info da lite com Instruction Book for senior Electrol...

Page 2: ...type installation use the wall type hanger and ceiling adapters as shown in Fig 3 on page 3 RECESSED ABOVE CEILING Other methods of installation will no doubt suggest themselves especially in new buil...

Page 3: ...Limit up switch knob controls stopping point of picture surface inside case 1 Level unit lengthwise with a carpenter s level and plum level CAUTION DO NOT COMPLETELY SEAL IN UNIT ACCESS ROOM MUST BE...

Page 4: ...sed position If necessary use the following procedures PICTURE SURFACE ROLLS TOO FAR INTO CASE 1 Lower picture surface approximately two feet with operating switch 2 Place operating switch in off posi...

Page 5: ...SHED WITH SCREEN SPST WITH CENTER OFF AC COMMON AC HOT 120 VAC 60 HZ 1 AMP MAX SIDE VIEW OF SWITCH BOX 120V WIRING DIAGRAM 240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH Da Lite offers two styles of...

Page 6: ...black and white leads Up Position Check for power at red and white leads e Let motor cool down for 15 min utes Try again f Disconnect motor leads and check for continuity between black and white wires...

Page 7: ...With power off turn roller by hand to free binding f Replace capacitor g Secure connection or replace wire 4 Scraping or grinding noise a If metal shipping bracket is left at tached to screen it may...

Page 8: ...Lite s option the defective part of the merchandise Returns for service should be made to your Da Lite dealer If it is necessary for the dealer to return the screen or part to Da Lite transportation e...