background image

8

Symptom

Cause

Solution

Screen jammed. Will not operate, 
motor hums, door open, closing 
mechanism detached from door.

Closing mechanism detached from door, 
allowing it to jam into box.

After securing fabric to roller, loosen set screws on 
motor gear and manually rotate solenoid assembly back 
over top of roller into position, then reattach door. Match 
flats on motor drive shaft to gear set screws  
and tighten.

Scraping or grinding noise.

If metal shipping bracket is left attached  
to screen, it may be rubbing on motor  
end of roller.

Remove shipping brace.

Gear noise.

Gear may need light weight grease.

Apply light weight grease.

Incorrect down limit switch setting.

Lost roller wrap.

See installation instructions.

Limit switch out of adjustment.

See door closure and timing instructions.

Door closes and screen  
continues to run upward.

Door limit out of adjustment.

Loosen nut holding limit switch. Rotate adjusting 
position, then secure.

Door limit switch is shorted.

Repair short or replace limit switch.

Troubleshooting

Summary of Contents for ExecutiveElectrol

Page 1: ...INSTRUCTION BOOK FOR Executive Electrol...

Page 2: ...Support Brackets 6 Do not remove metal shipping brace secures roller wrapping paper or tape until screen is installed NOTE Screen is not centered in box Screen is set 22 from motor end 7 Make sure to...

Page 3: ...en the picture surface is moving upward it is controlled by a limit switch that shuts off when the door closes To adjust for more or less picture drop viewing area proceed in the following manner Scre...

Page 4: ...6 x 16 Suggested Methods of Installation TYPE 1 2 Offset mounting recessed above ceiling for plaster dry wall or paneling Door painted same finish as ceiling TYPE 1 2 Allow 1 8 min clearance all aroun...

Page 5: ...Down Adj Black Down Red Up In Multiple Control Installations This Switch Is Replaced By The Low Voltage Control Operated From Push Button Stations Black With Yellow Up Down Off AC Hot AC Common 120V...

Page 6: ...eads Shut power off at breaker Remove wall switch and check for broken or loose connection Replace if defective Check LVC electrical checklist Thermal overload tripped excessive overheating Let motor...

Page 7: ...ive solenoid Check for power to the solenoid terminals If there is power replace solenoid Check blue wire between solenoid switch and solenoid It is either crimped or broken Repair or replace Fabric d...

Page 8: ...en Scraping or grinding noise If metal shipping bracket is left attached to screen it may be rubbing on motor end of roller Remove shipping brace Gear noise Gear may need light weight grease Apply lig...

Page 9: ...9...

Page 10: ...10...

Page 11: ...11...

Page 12: ...E MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties o...

Reviews: