Executive Electrol

®

 Installation

Black

Red (Up)

Blue

Black

White

White

Re

d

Up Limit Switch
(Operated By Door)

Capacitor

Black
(Down)

Down Limit Switch

Solenoid Switch

Whit

e (Common)

Motor: 120V.60 Cycles 1/10 HP Intermittent
Duty With Auto-Reset Thermal Protector

Internal 
Wiring

External Wiring 
to Be Completed 
By Installer

Junction Box Mounted In
Screen Case, In Which Internal
Wiring Terminates In
White, Black And Red Leads

Whit

e

Down 

Adj.

Black (Do

wn)

R

ed (Up)

In Multiple Control Installations This Switch 
Is Replaced By The Low Voltage Control, 
Operated From Push-Button Stations.

Black With Yellow

Up

Down

Off

AC Hot

AC Common

120V.Ac 60Hz. 
1 Amp. Max

Side View Of 
Switch & Box

Green

(Ground)

Black

Black

Blue

Red

Operating Switch, 
Switch Box, And 
Plate Furnished  
With Screen. (SPDT) 
With 

Center Off

This Switch Cannot Be Used With L.V.C.

Solenoid

120V Wiring Diagram

240 Volt Wiring Diagram  

For Standard Wall Switch:

Da-Lite offers two styles of 240 volt wall 
switches for standard operation. Please see 
wiring diagram included in wall switch box 
included with screen.

Summary of Contents for ExecutiveElectrol

Page 1: ...INSTRUCTION BOOK FOR Executive Electrol...

Page 2: ...Support Brackets 6 Do not remove metal shipping brace secures roller wrapping paper or tape until screen is installed NOTE Screen is not centered in box Screen is set 22 from motor end 7 Make sure to...

Page 3: ...en the picture surface is moving upward it is controlled by a limit switch that shuts off when the door closes To adjust for more or less picture drop viewing area proceed in the following manner Scre...

Page 4: ...6 x 16 Suggested Methods of Installation TYPE 1 2 Offset mounting recessed above ceiling for plaster dry wall or paneling Door painted same finish as ceiling TYPE 1 2 Allow 1 8 min clearance all aroun...

Page 5: ...Down Adj Black Down Red Up In Multiple Control Installations This Switch Is Replaced By The Low Voltage Control Operated From Push Button Stations Black With Yellow Up Down Off AC Hot AC Common 120V...

Page 6: ...eads Shut power off at breaker Remove wall switch and check for broken or loose connection Replace if defective Check LVC electrical checklist Thermal overload tripped excessive overheating Let motor...

Page 7: ...ive solenoid Check for power to the solenoid terminals If there is power replace solenoid Check blue wire between solenoid switch and solenoid It is either crimped or broken Repair or replace Fabric d...

Page 8: ...en Scraping or grinding noise If metal shipping bracket is left attached to screen it may be rubbing on motor end of roller Remove shipping brace Gear noise Gear may need light weight grease Apply lig...

Page 9: ...9...

Page 10: ...10...

Page 11: ...11...

Page 12: ...E MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties o...

Reviews: